HS6E-L44B03-G IDEC Corporation, HS6E-L44B03-G Datasheet

no-image

HS6E-L44B03-G

Manufacturer Part Number
HS6E-L44B03-G
Description
SAFETY INTERLOCK SWITCH SPRING LOCK WITH UN-LOCKING SOLENOID 3M CABLE TYPE L CIR
Manufacturer
IDEC Corporation
Datasheet

Specifications of HS6E-L44B03-G

Contact Form
1 NC, 1 NC
Current, Rating
50 A
Dielectric Voltage
300 V
Ip Rating
IP67
Operation
0.05 to 1.0 m/s
Special Features
Green Indicator Light
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
-25 °C
Voltage, Rating
250 V
Compact Body
75 × 15 × 75 mm
Energy Saving. 24 Vdc, 110 Ma (solenoid
100 mA, LED
Lead Free Status / Rohs Status
RoHS Compliant part
Door Interlock Switches
HS6E features:
Spring Lock Type
Solenoid Lock Type
Mechanism
Spring Lock
Compact body: 75 × 15 × 75 mm
15-mm-wide, thinnest solenoid type interlock switch in the world.
Reversible mounting and angled cable allow four actuator insertion directions.
Energy saving. 24V DC, 110 mA (solenoid: 100 mA, LED: 10 mA)
Manual unlocking possible on three sides.
RoHS compliant
LED indicator shows solenoid operation
Automatically locks the actuator without power applied to the solenoid
After the machine stops, unlocking is completed by the solenoid
Manual unlocking is possible on three sides in the event of power failure
or maintenance
The actuator is locked when energized.
The actuator is unlocked when de-energized.
Flexible locking function can be achieved, for an application where locking is not
required and sudden stopping of a machine must be prevented
Lock
The contact confi gurations show the contact status when the actuator is inserted and locked.
LED color is G (green) only.
Actuator keys are not supplied with the interlock switch and must be ordered separately.
Number
Circuit
M
N
P
L
Main Circuit: 1NC + 1NC, Monitor Circuit: 2NC/1NO
Main Circuit: 1NC + 1NC, Monitor Circuit: 2NC/1NC
Main Circuit: 1NC + 1NC, Monitor Circuit: 1NC,
1NO/1NO
Main Circuit: 1NC + 1NC, Monitor Circuit: 1NC,
1NO/1NC
HS6E Subminiature Interlock Switches with Solenoid
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Main Circuit:
Monitor Circuit:
Monitor Circuit:
Contact Confi guration
(Actuator inserted) (Solenoid OFF)
Direct Opening
11
21
31
11
21
31
11
21
33
11
21
33
Action
USA: 800-262-IDEC
12
22
32
12
22
32
12
22
34
12
22
34
(+)
(+)
A2
A2
Installation
41
53
41
53
41
53
41
51
Double
Part Numbers
42
54
42
52
42
54
42
52
(–)
(–)
A1
A1
Length
Cable
1m
3m
5m
1m
3m
5m
1m
3m
5m
1m
3m
5m
Canada: 888-317-IDEC
HS6E-M44B03-G
(Standard Stock
HS6E-N44B03-G
HS6E-P44B03-G
HS6E-L44B03-G
HS6E-M44B01-G
HS6E-M44B05-G
HS6E-N44B01-G
HS6E-N44B05-G
HS6E-L44B01-G
HS6E-L44B05-G
HS6E-P44B01-G
HS6E-P44B05-G
Part Number
in bold)
Part Number Key
HS6E - L 4 4 B 01 - G
Circuit Code
Main Circuit
L: 1NC + 1NC
M: 1NC + 1NC
N: 1NC + 1NC
P: 1NC + 1NC
HS6E Series
Solenoid Unit Voltage/
Lock Mechanism
4: Spring Lock
7Y: Solenoid Lock
Door Monitor Circuit Lock Monitor Circuit
Indicator Rated Voltage
4 (24V DC)
Blank (without indicator)
1NC, 1NO
1NC, 1NO
2NC
2NC
Housing Color
B (Black)
Cable Length
01: 1m
03: 3m
05: 5m
Indicator
Color
G (Green)
1NO
1NC
1NO
1NC
365

Related parts for HS6E-L44B03-G

HS6E-L44B03-G Summary of contents

Page 1

... The contact confi gurations show the contact status when the actuator is inserted and locked. LED color is G (green) only. Actuator keys are not supplied with the interlock switch and must be ordered separately. Double Installation Action Part Numbers Part Number Cable (Standard Stock Length in bold) (+) (+) (–) (– HS6E-L44B01-G 3m HS6E-L44B03 HS6E-L44B05 HS6E-M44B01 HS6E-M44B03 ...

Page 2

... HS6E Series Lock Circuit Mechanism Number Main Circuit: 1NC + 1NC, Monitor Circuit: 2NC/1NO L Main Circuit: Monitor Circuit: Monitor Circuit: Main Circuit: 1NC + 1NC, Monitor Circuit: 2NC/1NC Main Circuit: M Monitor Circuit: Monitor Circuit: Solenoid Lock Main Circuit: 1NC + 1NC, Monitor Circuit: 1NC, 1NO/1NO ...

Page 3

... AC/DC, 100 mA) (operating frequency 900 operations/hr) Conditional Short-circuit Current 50A (250V) (Use 250V/10A fast-blow fuse for short-circuit protection.) Cable UL2464, No. 22 AWG (12-core: 0.3 mm Cable Diameter ø7.6 mm Weight Approx. 200g 2 (10G) 2 (100G) or equivalent/core) 2 USA: 800-262-IDEC Canada: 888-317-IDEC HS6E Series 367 ...

Page 4

... HS6E Series Solenoid/Indicator Locking Mechanism Rated Voltage Current Coil Resistance Pickup Voltage Dropout Voltage Solenoid Maximum Continuous Applicable Voltage Maximum Continuous Applicable Time Insulation Class Light Source Indicator Illumination Color Contact Ratings Rated Insulation Voltage (Ui) Operating temperature (–25 to 35ºC) Rated Thermal ...

Page 5

... Screw (ø4 tapped hole When using right-angle actuator (HS9Z-A62) 22.6 ±1 (14) Actuator Stop (supplied) USA: 800-262-IDEC Canada: 888-317-IDEC HS6E Series 3-M4 Screw (ø4 tapped hole) 28.5 41 Hole for Manual Unlocking ø12 (reference) 28.5 41.8 When using horizontal/vertical angle adjustable actuator (HS9Z-A65/A66) (25) 22 ...

Page 6

... HS6E Series Straight Actuator (HS9Z-A61) 20.9 43.2 (15. 0.8 Note 1 2-ø9 Actuator Stop (supplied) Rubber Bushing The actuator stop is used to adjust the actuator position. Remove after the actuator position is mounted. Angle Adjustable Actuator (HS9Z-A65) Horizontal Adjustment 0.8 Orienting Insert Angle Adjustment ...

Page 7

... Door Interlock Switches Circuit Diagrams and Operating Characteristics Spring Lock Type Interlock Switch Status Door Status Circuit Diagram (Example: HS6E-N4) Door Main Circuit 11-42 Door Door Lock Lock HS6E-L4 Monitor Monitor Monitor Monitor Door Monitor Circuit (door closed) 21-22 (+) (+) (– ...

Page 8

... HS6E Series Solenoid Lock Type Interlock Switch Status Door Status Circuit Diagram (Example: HS6E-N7Y) Door Main Circuit 11-42 Door Door Lock Lock HS6E-L7Y Door Monitor Circuit Monitor Monitor Monitor Monitor (door closed) 21-22 (+) (+) (–) (– Door Monitor Circuit (door closed) 31-32 ...

Page 9

... Door Hinge Door Hinge Door Hinge Label Door Hinge Door Hinge Label Door Hinge USA: 800-262-IDEC Canada: 888-317-IDEC HS6E Series Application on Hinged Doors HS9Z-A62S Actuator Door HS9Z-A61 Actuator HS6E Interlock Switch Latch Door Stop 373 ...

Page 10

... HS6E Series For Manual Unlocking Spring lock type The HS6E allows manual unlocking of the actuator to pre-check proper door operation before wiring or turning power on, as well as for emergency use such as a power failure. Solenoid lock type The HS6E can be unlocked manually in an emergency. ...

Page 11

... Note: The contact arrangements show the contact status when the actuator is inserted and locked. Insulation Color White Black Pink/White Brown/White Brown Blue Lock Monitor (+) (– White Black 41 42 Blue/White 53 54 Pink Pink/White 41 42 Blue/White 51 52 Pink Pink/White Blue/White 53 54 Pink Pink/White Blue/White 51 52 Pink Pink/White USA: 800-262-IDEC Canada: 888-317-IDEC HS6E Series 375 ...

Page 12

... Entry of a considerable amount of foreign objects into the switch may affect the mechanism of the switch and cause a breakdown. • Do not store the switches in a dusty, humid, or organic-gas atmosphere. HS5E/HS5B Precautions Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure of the correct operation before installation. ...

Page 13

... When opening the hole, apply proper protection against water or other foreign objects. 2. Caution: After the unlocking operation, put the screw back into the unlocking entry for safety. Plug Screwdriver HS1C Precautions www.idec.com Door Interlock Switches Unlock Unlock Normal Position Manual Unlocking Position 89 Screwdriver ...

Page 14

... Door Interlock Switches Applicable Crimping Terminals • (Refer to the Crimping Terminal shown in the drawing below.) • HS1C Terminals No Use solid or stranded wires only (crimping terminals not applicable). Terminals No. 7 and 8: Crimping Terminal 1 Ground Terminal: Crimping Terminal 2 • HS1B Ground Terminal: Crimping Terminal 2 ...

Page 15

... K-MECS) and a gasket (Part No.: GP M20, K-MECS). Install a gasket between the interlock switch and the adapter. Apply sealing tape between the cable gland and the adapter to make sure of IP67 protection for the enclosure. www.idec.com Door Interlock Switches Door Hinge Door Hinge Door Hinge ...

Related keywords