WLD-TS Omron Automation, WLD-TS Datasheet - Page 2

no-image

WLD-TS

Manufacturer Part Number
WLD-TS
Description
Switch, Limit, ROBUST, GENERAL PURPOSE, TOP PIN PLUNGER
Manufacturer
Omron Automation
Type
Limitr
Datasheet

Specifications of WLD-TS

Actuator Type
Plunger
Contact Form
SPST
Current, Rating
10 AAC/ADC
Dielectric Strength
1000/2200 VAC
Ip Rating
IP67
Mounting Hole Size
5.2 mm
Number Of Poles
1
Operating Force
6 lbs.
Operation
Snap Action
Temperature, Operating
-10 to +80 °C
Voltage, Rating
500/250 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Characteristics
Ratings (AC): Inductive load
Ratings (DC): Non-Inductive load
Ratings (DC): Inductive load
Explanation
Inrush current
Protective circuit
Conduit size
Earth terminal
Ambient temperature
Ambient humidity
Permissible operating speed
Permissible operating frequency (Mechanically)
Permissible operating frequency (Electrically)
Contact resistance
Insulation resistance
Dielectric strength
Durability (Mechanically)
Durability (Electrically)
Pollution degree
Vibration resistance (Malfunction)
Shock resistance (Destruction)
Shock resistance (Malfunction)
Degree of protection
Rated voltage: 125 VAC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 5 A (NC) 2.5 A
(NO)
Rated voltage: 250 VAC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 3 A (NC) 1.5 A
(NO)
Rated voltage: 500 VAC, Inductive load: 3 A (NC) 3 A (NO), Motor load: 1.5 A (NC) 0.8 A
(NO)
Rated voltage: 8 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 6 A (NC) 3 A (NO)
Rated voltage: 14 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 6 A (NC) 3 A (NO)
Rated voltage: 30 VDC, Resistive load: 6 A (NC) 6 A (NO), Lamp load: 4 A (NC) 3 A (NO)
Rated voltage: 125 VDC, Resistive load: 0.8 A (NC) 0.8 A (NO), Lamp load: 0.2 A (NC) 0.2
A (NO)
Rated voltage: 250 VDC, Resistive load: 0.4 A (NC) 0.4 A (NO), Lamp load: 0.1 A (NC) 0.1
A (NO)
Rated voltage: 8 VDC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 6 A (NC) 6 A (NO)
Rated voltage: 14 VDC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 6 A (NC) 6 A (NO)
Rated voltage: 30 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load: 4 A (NC) 4 A (NO)
Rated voltage: 125 VDC, Inductive load: 0.8 A (NC) 0.8 A (NO), Motor load: 0.2 A (NC) 0.2
A (NO)
Rated voltage: 250 VDC, Inductive load: 0.4 A (NC) 0.4 A (NO), Motor load: 0.1 A (NC) 0.1
A (NO)
The above values indicate the steady-state current. Lamp load has an inrush current of 10
times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a
time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-
state current.
NC: 30 A
NO: 20 A
Classification of protection against electric shock: Class I
Short-circuit protective device: 10 A fuse type gI or gG (IEC269)
1/2-14NPT
With ground terminal
Operating: -10 CEL to 80 CEL
(with no icing or condensation)
Operating: 35%RH to 95%RH
(with no icing or condensation)
1 mm/s to 0.5 m/s
120 operations / 1 minute Max.
30 operations / 1 minute Max.
25 m Ohm Max. (Initial value)
(Measuring method is contact resistance meter.)
Between each terminal of the same polarities: 100 M Ohm Min.
Between live-metallic part and ground: 100 M Ohm Min.
Between each terminal and non-live-metallic part: 100 M Ohm Min.
(at 500 VDC Megger)
Between each terminal of the same polarities: 1,000 VAC
Between live-metallic part and ground: 2,200 VAC
Between each terminal and non-live-metallic part: 2,200 VAC
(50/60 Hz for 1 min)
15,000,000 operations Min. (No load)
(Temperature, Humidityconditions: 5 CEL to 35 CEL, 40 %RH to 70 %
RH)
750,000 operations Min. (Resistive load 10 A at 125 VAC)
(Temperature, Humidityconditions: 5 CEL to 35 CEL, 40 %RH to 70 %
RH)
3 (EN60947-5-1)
Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm,
Contact opening: 1 ms Max. at the free position and the total travel
position.
1,000 m/s2
Contact opening is 1 ms Max. at the free position and the total travel
position at 300 m/s2.
IEC60529 (JEM): IP67
NEMA250: Type3,4,13