LCA30S-48 Cosel U.S.A. Inc., LCA30S-48 Datasheet - Page 2

no-image

LCA30S-48

Manufacturer Part Number
LCA30S-48
Description
Power Supply, Switching; 33.6 W (Max.); 85 to 132 VAC (1 Phase)/110 to 170 VDC
Manufacturer
Cosel U.S.A. Inc.
Type
Industrialr
Datasheet

Specifications of LCA30S-48

Brand/series
LC Series
Configuration
Open-Frame
Current, Input
0.7 A (Typ.)
Current, Output
0.7 A
Dimensions
50 mm W x 25 mm H x 132.5 mm D
Frequency, Operating
47 to 440 Hz
Line Regulation
192 mV (Max.)
Load Regulation
300 mV (Max.)
Mounting Type
Panel
Number Of Outputs
1
Operation
Switching
Output
48 VDC @ 0.7 A
Power, Output
33.6 W
Power, Rating
33.6 W (Max.)
Primary Type
AC-DC
Temperature, Operating
-10 to 60°C
Voltage, Input
85 to 132/110 to 170 VAC/VDC
Voltage, Output
48 VDC
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LCA30S-48
Manufacturer:
COSEL
Quantity:
323
LCA
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
SPECIFICATIONS
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*1
*2
*
E-64
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.
Avoid prolonged use under over-load.
R
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A] ACIN 100V 25typ ( Io=100% ) ( At cold start )
LEAKAGE CURRENT[mA] 0.5max ( 60Hz , According to UL , CSA and DEN-AN )
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV] 40max
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV] 50max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6
OUTPUT VOLTAGE SETTING[V] xx
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION 4.00V min
OPERATING INDICATION Not provided
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP. , HUMID.AND ALTITUDE -10 to +60 C , 20 - 90%RH ( Non condensing ) ( Refer to DERATING CURVE ), 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -20 to +75 C , 20 - 90%RH ( Non condensing ), 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
Rugged PCB type
LCA30S
ACIN 100V 0.7typ ( Io=100% )
0 to +50 C
-10 - 0 C
0 to +50 C
-10 - 0 C
* 1
* 1
* 1
* 1
* 2
LCA30S-3
18
3V 6A
LCA30S-3
AC85 - 132 1 f or DC110 - 170
47 - 440 or DC
69typ
3
6
20max
80max
140max
120max
160max
20max
100max ( ACIN 85V , Io=100% )
10typ ( ACIN 85V , Io=100% ) 20typ ( ACIN 100V , Io=100% )
Not provided
Not provided
AC2 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 10mA , DC500V 50M W min ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA , DC500V 50M W min ( At Room Temperature )
10 - 55Hz , 19.6m/s
196.1m/s
UL60950-1 , CSA C22.2 No.234 Complies with DEN-AN
Complies with FCC-B , VCCI-B
50 X 25 X 132.5mm ( W X H X D ) / 150g max
Convection
2
( 20G ), 11ms , once each X , Y and Z axis
LCA30S-5
30
5V 6A
LCA30S-5
75typ
5
6
20max
40max
80max
140max
120max
160max
50max
20max
Fixed ( "Y"which can be adjusted the output is available as optional:5V -5 to +10% : 12 , 15 , 24 , 36 , 48V t 10% )
4.9 - 5.3
Works over 115% of rating , by zener diode clamping
2
( 2G ), 3minutes period , 60minutes each along X , Y and Z axis
LCA30S-12
30
12V 2.5A
LCA30S-12
80typ
12
2.5
48max
100max
120max
160max
150max
180max
120max
48max
11.5 - 12.5
1
Ordering information
LC
LCA30S-15
30
15V 2A
LCA30S-15
81typ
15
2
60max
120max
120max
160max
150max
180max
150max
60max
14.4 - 15.6
2
A
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The Noise Filter is recommended
*to connect with several devices.
Recommended Noise Filter
NAC-06-472
3
LCA30S-24
31.2
24V 1.3A
LCA30S-24
82typ
24
1.3
96max
150max
120max
160max
150max
180max
240max
96max
23.0 - 25.0
30
4
S
LCA30S-36
32.4
36V 0.9A
LCA30S-36
80typ
36
0.9
144max
240max
150max
200max
250max
300max
360max
144max
34.5 - 37.5
1Series name
2100/120V input
3Output wattage
4Single output
5Output voltage
6Optional
C :with Coating
G :Low leakage current
Y :with Potentiometer
5
-5
LCA30S-48
33.6
48V 0.7A
LCA30S-48
80typ
48
0.7
192max
300max
150max
200max
350max
400max
480max
192max
46.0 - 50.0
6
-O