VQ1100N-51 SMC Corporation, VQ1100N-51 Datasheet - Page 81

no-image

VQ1100N-51

Manufacturer Part Number
VQ1100N-51
Description
SOLENOID VALVE, 5 PORT, BASE MOUNTED, PLUG IN TYPE, 24VDC, -COM
Manufacturer
SMC Corporation
Type
Solenoidr
Datasheet

Specifications of VQ1100N-51

Brand/series
VQ Series
Configuration
2-Position Single
Enclosure Rating
IP65
Fluid Type
Air/Inert Gas
Number Of Ports
5
Pressure, Operating
0.7 MPa
Primary Type
Solenoid Valve
Temperature, Ambient
–10° to +50°C
Valve Type
5-Port Solenoid, Plug-In, Base Mounted with 2 Position Actuation, Rubber Seal, Negative Common
Voltage, Coil
24 VDC
The manual override is locked by sliding it all the way to the pilot
valve side (ON side) with a small flat head screwdriver or finger.
Slide it to the fitting side (OFF side) to release it. In addition, it
can also be used as a push type by using a screwdriver, etc., of
ø1.7 or less. (ø2 or less for VQ2000).
Removing
1. Loosen the clamp screw until it turns freely. (The screw is cap-
2. Lift the coil side of the valve body while pressing down slightly
tive.)
on the screw head and remove it from the clamp bracket B.
When the screw head cannot be pressed easily, gently press
the area near the manual override of the valve.
Slide locking type (Manual) <Semi-standard>
Bore ø1.7
Warning
OFF
Caution
Bore ø2
How to Mount/Remove Solenoid Valves
ON
Clamp bracket A
VQ1000
VQ2000
Bore ø2
OFF
Clamp bracket B
ON
Series
Specific Product Precautions 2
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC
Products (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Manual Override
OFF
Orange
OFF position
ON
Orange
OFF position
VQ1000/2000
Clamp screw
Green
ON position
Green
ON
position
Mounting
1. Press down on the clamp screw. Clamp bracket A opens. Di-
2. Press the valve body downward. (When the screw is released,
3. Tighten the clamp screw. (Proper tightening torque: VQ1000,
The cylinder port fittings are a cassette for easy re-
placement. The fittings are blocked by a clip. Take out
the clip with a flat head screwdrier, etc., then replace
the fittings.
For mounting, insert the fitting assembly until it
strikes against the inside wall and then insert the clip
to the specified position.
1. Use caution that O-rings must be free from scratches and dust. Other-
2. After screwing in the fittings, mount the M5 fitting assembly on the
3. Purchasing order is available in units of 10 pieces.
Applicable tubing ø5/32"
Applicable tubing ø5/16"
Applicable tubing ø1/8"
Applicable tubing ø1/4"
Applicable tubing ø3.2
Refer to “Manifold Optional Parts” on pages 66, 67, 73 for other types of fittings.
Applicable tubing O.D.
Applicable tubing ø4
Applicable tubing ø6
Applicable tubing ø8
Caution
Caution
wise, air leakage may result.
manifold base. (Tightening torque: 0.8 to 1.2 N·m)
agonally insert the hook on the valve end plate side into clamp
B.
it will be locked by clamp bracket A.)
0.25 to 0.35 N·m; VQ2000, 0.5 to 0.7 N·m.)
Dust on the sealing surface of the gasket or solenoid valve can cause
air leakage.
Caution
Caution
How to Mount/Remove Solenoid Valves
Replacement of Cylinder Port Fittings
M5
Clip
Fitting assembly
VQ1000
VVQ1000-50A-M5
VVQ1000-50A-C3
VVQ1000-50A-C4
VVQ1000-50A-C6
VVQ1000-50A-N1
VVQ1000-50A-N3
VVQ1000-50A-N7
VQ1000
Fitting assembly part no.
VQ2000
VVQ1000-51A-C4
VVQ1000-51A-C6
VVQ1000-51A-C8
VVQ1000-51A-N3
VVQ1000-51A-N7
VVQ1000-51A-N9
Clip
Back page 4
VQ2000
Fittings
assembly

Related parts for VQ1100N-51