FPG-PP21 Panasonic Electric Works, FPG-PP21 Datasheet - Page 5

no-image

FPG-PP21

Manufacturer Part Number
FPG-PP21
Description
EXPANSION UNIT, 2 AXIS, 500KHZ TRANSISTOR OUTPUT UNIT
Manufacturer
Panasonic Electric Works
Type
I/Or
Datasheet

Specifications of FPG-PP21

Brand/series
FPG Series
Primary Type
Expansion
For Use With
Modular Controllers
FP
I High-speed counter, Pulse output and PWM output Specifications
Notes: 1) The contacts noted above cannot be allocated for more than one fuction. Also, contacts that are not assigned to the various functions can be used as general inputs/outputs. Inputs
I Serial communication Specifications
Notes: 1) In order to use the serial communication function (1:1 communication), a RS232C
I Serial communication Specifications
Notes: 1) In order to use the serial communication function (1:N communication), a RS485
12
Communication method
Synchronous method
Transmission line
Transmission distance
Transmission speed (Baud rate)
Interface
Communication method
Synchronous method
Transmission line
Transmission distance
(Total distance)
Transmission speed
(Baud rate)
Number of units (stations)
Interface
High-speed counter
Pulse output
PWM output
(1:1 communication)
(1:N communication)
2) If using pulse output or PWM output, one channel of the two-phase high-speed counter is used for each output point, in each case. If only one pulse output point is being used,
2) The transmission speed (baud rate) and transmission format are specified using
2) The transmission speed (baud rate) and transmission format are specified using
3) Unit (station) numbers are specified using the system registers. Up to 31 units
X0 to X5 are pulse catch inputs, and can also be used for interrupt inputs.
either one point of the two-phase high-speed counter or three points of the single-phase high-speed counter may be used.
type communication cassette is required.
the system registers.
type communication cassette is required.
the system registers.
(stations) can be set, using the switches on the control unit.
Σ
Item
Item
Input point number
Maximum counting speed
Input mode
Input contact used (see note 1)
Output point number
Output mode
Maximum output frequency
High-speed counter used (see note 2)
Input/Output contact used
(see note 1)
Output point number
Output frequency
Output duty
High-speed counter used (see note 2)
Output contact used (see note 1)
Two-wire, half duplex transmission
Start stop synchronous system
Twisted-pair cable or VCTF
Maximum 1,200 m
(see notes 4 and 5)
2,400 bits/s to 115.2 k bits/s
19,200 bits/s when a C-NET adapter is connected
(see notes 2, 4 and 5)
Maximum 99 units (stations)
32 units (stations) max. when a C-NET adapter is
connected (see notes 3, 4 and 5)
Conforming to RS485
(connected via the terminal block)
Item
Half duplex transmission
Start stop synchronous system
RS232C
15 m
2,400 bits/s to 115.2 k bits/s (see note 2)
Conforming to RS232C
(connected via the terminal block)
(see note 1)
(see note 1)
49.21 ft.
3,937 ft.
Description
Description
Single-phase: max. 4 channels
Single-phase:
Single-phase:
Single-phase:
Two independent points (simultaneous output possible)
CW and CCW mode, pulse and direction mode
1 channel: max. 100 kHz (x 1)
2 channels: max. 60 kHz (x 2)
Two-phase CH0 or CH2
X2 or X5: home input
Y0 or Y3: CW output or pulse output
Y1 or Y4: CCW output or direction output
Y2 or Y5: deviation counter reset output
Two points (Y0, Y3)
1.5 to 12.5 k Hz (at resolution of 1,000), 15.6 k to 41.7 k Hz (at resolution of 100)
0.0 to 99.9% (at resolution of 1,000), 1 to 99% (at resolution of 100)
Two-phase CH0 or CH2
Y0 or Y3
for 1 channel: max. 50 kHz (x 1)
for 2 channels: max. 30 kHz (x 2)
for 3 or 4 channels: max. 20 kHz (x 3 or 4)
incremental, decremental
X0: count input (CH0)
X1: count input (CH1)
X2: reset input (CH0, CH1)
X3: count input (CH2)
X4: count input (CH3)
X5: reset input (CH2, CH3)
I PLC link function Specifications
Notes: 1) A RS485 type communication cassette is required in order to use the PLC link
Communication method
Transmission method
Transmission line
Transmission distance
(Total distance)
Transmission speed (Baud rate)
Number of units (stations)
PLC link capacity
Interface
2) Unit (station) numbers are specified using the switches on the control unit or the
4) When connecting a commercially available device that has an RS485 interface,
5) The values for the transmission distance, transmission speed (baud rate), and
function.
system registers.
please confirm operation using the actual device. In some cases, the number of
units (stations), transmission distance, and transmission speed (baud rate) vary
depending on the connected device.
number of units (stations) should be within the values noted in the graph below.
Number
of units
(stations)
Item
For a transmission speed of 2,400 bits/s to 38.4 k bits/s, you can
set up a maximum of 99 units (stations) and a maximum transmission
distance of 1,200 m.
99
70
40
0
Description
Transmission distance (m)
Two-phase: max. 2 channels
Two-phase:
Two-phase:
Two-phase:
(linear interpolation function: max. 100 kHz
circular interpolation function: max. 20 kHz)
for 1 channel: max. 20 kHz (x 1)
for 2 channels: max. 15 kHz (x 2)
two-phase, incremental/decremental,
incremental/decremental control
X0, X1: count input (CH0)
X2: reset input (CH0)
X3, X4: count input (CH2)
X5: reset input (CH2)
Token bus
Floating master method
Twisted-pair cable or VCTF
1,200 m
115.2 k bits/s
Maximum 16 units (see note 2)
Link relay: 1,024 points, link register: 128 words
Conforming to RS485
(connected via the terminal block)
700
For transmission speed 115.2 k bits/s
3,937 ft.
1000 1200
Description
For transmission
speed 57.6 k bits/s
(see note 1)