NBH-30-432 Cosel U.S.A. Inc., NBH-30-432 Datasheet - Page 2

no-image

NBH-30-432

Manufacturer Part Number
NBH-30-432
Description
NOISE FILTER, SINGLE PHASE, 250 VAC, 30A, 0.5/1.0 MA, 1.56 MH1, 1.56 MH2, 1 UF,
Manufacturer
Cosel U.S.A. Inc.
Type
Filterr
Datasheet

Specifications of NBH-30-432

Brand/series
NBH Series
Current, Leakage
0.5/1 μA
Current, Rating
30 A
Dimensions
104mmH×43mmW×53mmL
Filter Type
Noise
Mounting Type
DIN Rail
Phase
1
Primary Type
2-Stage, AC
Voltage, Operating
250 VAC
Voltage, Rating
250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Filter
Noise
Ultra high-attenuation type of common mode noise from 10kHz to 10MHz (2-stage filter)
- Single Phase 250 VAC
- Withstand voltage 4,000 VAC
Specifications
* 1
I-2
DIN rail installation type is option
No.
10
11
12
13
14
1
2
3
4
5
6
7
8
9
(Line to ground capacitor code -000 to -471)
When the line to ground capacitor code is different, the test voltage characteristic is different. (See table 1.1)
LINE
Features of NBH series
Circuit Diagram
CY1,CY2 : Line to ground capacitor
1
2
Items
Rated Voltage[V]
Rated Current[A]
Test Voltage (Terminal-Mounting Plate)
Isolation Resistance (Terminal-Mounting Plate)
Leakage current 125/250V 60Hz
Voltage drop
Safety agency approval temperatures
Operating temperature
Operating humidity
Storage temperature/humidity
Vibration
Impact
Safety agency approvals
Case size (without projection) /Mass
Case
Ultra high-attenuation type of common mode noise from 10kHz to 10MHz (2-stage filter)
NBH series
CY1
CY1
The terminal cover is retracted inside the unit
: Mounting Plate
CY2
CY2
* 1
AC 1f 250 / DC250
6
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
500 VDC 100MW min at room temperature and humidity
0.5mA/1.0mA max
1.0V max
-25 to +85C (Refer to Derating Curve A)
-40 to +85C (Refer to Derating Curve A)
20 to 95%RH (Non condensing)
-40 to +85C/20 to 95%RH (Non condensing)
10 to 55Hz, 19.6m/s
196.1m/s
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
53X43X104 mm (WXHXD) /320g max (Option : -D refer to external view)
3
4
NBH-06-432
LOAD
2
(20G), 11ms Once each X, Y and Z axis
- Quick and easy push-down terminal
10
NBH-10-432
2
(2G), 3min. Period, 1hour each X, Y and Z axis
Just connect the wires, push down and tighten
the screws with a screwdriver
1
1Model Name
2Rated Current
3Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
*
4Options
NBH -10 -432
Code
Ordering information
When the line to ground capacitor code is different, the attenuation
000
101
221
331
471
681
102
202
322
432
characteristic is different.
D :DIN rail installation type
* The dimensions change when the option is set.
Refer to External view.
Derating Curve
100
100
12.5
25
37.5
50
75.5
(Input 125/250V 60Hz)
80
60
40
20
80
60
40
20
5
0.13 mA/ 0.25mA max
0.25 mA/ 0.5 mA max
0.38 mA/ 0.75mA max
0.5 mA/ 1.0 mA max
0
-40
0
-40
Leakage Current
2
Derating Curve (A) 6,10A
Derating Curve (B) 16 to 30A
A/ 10 A max
A/ 25 A max
A/ 50 A max
A/ 75 A max
A/ 100 A max
A/ 150 A max
16
-25 to +85C (Refer to Derating Curve B)
-40 to +85C (Refer to Derating Curve B)
NBH-16-432
-30
-30
3
-20
-20
Ambient Temperature [C]
Ambient Temperature [C]
Line to ground
capacitor
(nominal value)
Not Provided Not Provided
1000pF Not Provided
1000pF
2200pF
3300pF
40
40
100pF Not Provided
220pF Not Provided
330pF Not Provided
470pF Not Provided
680pF Not Provided
CY1
45
20
NBH-20-432
4
50
50
-O
1000pF
1000pF
1000pF
CY2
60
60
(Terminal- Mounting Plate)
70
70
Test voltage
30
NBH-30-432
4,000VAC
2,500VAC
80 85
80 85
90
90

Related parts for NBH-30-432