MODEL 41/AL111DR Honeywell, MODEL 41/AL111DR Datasheet - Page 3

no-image

MODEL 41/AL111DR

Manufacturer Part Number
MODEL 41/AL111DR
Description
Sensor, Load Cell, Pancake, 5000 LBF, Tension Only
Manufacturer
Honeywell
Datasheet

Specifications of MODEL 41/AL111DR

Body Style
Pancake
Function
Pressure
Output
Voltage/Current
Primary Type
Pressure
Range, Measurement
5000 lbs.
Sensing Mode
Strain Gauge
Technology
Piezoelectric
Termination
6-Wire Connector
Voltage, Supply
10 VDC
Voltage, Switching
3 mV/V
iNTERNAL AMPLIFIERS
* Black and green wires are internally connected.
** Pins B and C are internally connected.
*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.
ALLOWABLE MAXIMUM LOADS
Capacity (lb)
5 to 25
50 to 1000
2000 to 5000
7500 to 30000
50000 to 100000
150000 to 200000
300000
400000
500000
Amplifier
specifications
Output signal
Input power (voltage)
Input power (current)
Freq. response
Power supply rejection
Operating temperature
Reverse volt. protection
Short circuit protection
Wiring code: connector
Wiring code: cable
Side load
(lb)
50 %
45 %
30 %
20 %
20 %
20 %
20 %
20 %
20 %
Voltage out-
put: Option 2b
±5 V
±15 Vdc or 26-32
Vdc
45 mA
3000 Hz
60 db
-20 °F to 185 °F
Yes
Momentary
A (+) Supply
B Output common
C Supply return
D (+) Output
E Shunt Cal 1
F Shunt Cal 2
R (+) Supply
Bl Output common
G Supply return
W (+) Output
B Shunt Cal 1
Br Shunt Cal 2
Bending
(lb-in)
40 %
35 %
25 %
20 %
20 %
20 %
20 %
20 %
20 %
Voltage out-
put: Option 2c
0-5 V or ±5 V @
45 mA
11 Vdc to 28 Vdc
40 mA
3000 Hz
60 db
-20 °F to 185 °F
Yes
Momentary
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt Cal 1
F Shunt Cal 2
R (+) Supply
Bl Output com*
G Supply return*
W (+) Output
B Shunt Cal 1
Br Shunt Cal 2
Torque
(lb-ft)
25 %
25 %
25 %
15 %
15 %
15 %
10 %
10 %
10 %
Voltage out-
put: Option 2t
0-10 V or ±10 V
@ 45 mA
15 Vdc to 28 Vdc
40 mA
3000 Hz
60 db
-20 °F to 185 °F
Yes
Momentary
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt Cal 1
F Shunt Cal 2
R (+) Supply
Bl Output com*
G Supply return*
W (+) Output
B Shunt Cal 1
Br Shunt Cal 2
Precision Low Profile Load Cell
Current three-
wire: Option 2j
4 mA to 20 mA
22 Vdc to 32 Vdc
65 mA
2500 Hz
60 db
0 °F to 185 °F
Yes
Yes
A (+) Supply
B Output common**
C Supply return**
D (+) Output
E Shunt Cal 1
F Shunt Cal 2
R (+) Supply
Bl Output com*
G Supply return*
W (+) Output
B Shunt Cal 1
Br Shunt Cal 2
Honeywell • Sensing and Control 3
Current two-
wire: Option
2k
4 mA to 20 mA
15 Vdc to
40 Vdc
4 mA to 28 mA
300 Hz
60 db
0 °F to 185 °F
Yes
Yes
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
R (+) Supply
Bl (+) Output
W Case ground
Intrinsically
safe amp: Op-
tion 2n (2N)***
4 mA to 20 mA
9 Vdc to
28 Vdc
4 mA to 24 mA
2000 Hz
60 db
-20 °F to 185 °F
Yes
Yes
A (+) Supply
B No connection
C No connection
D (+) Output
E Case ground
F No connection
R (+) Supply
Bl (+) Output
W Case ground

Related parts for MODEL 41/AL111DR