NAV2000-N02-3DZ SMC Corporation, NAV2000-N02-3DZ Datasheet - Page 10

no-image

NAV2000-N02-3DZ

Manufacturer Part Number
NAV2000-N02-3DZ
Description
Valve; 1/4 in.; NPT; 1/4; 1 MPa; 1.5 MPa; 0 to degC; (N)AV 2000 Series
Manufacturer
SMC Corporation
Datasheet

Specifications of NAV2000-N02-3DZ

Body Size
1⁄4
Brand/series
(N)AV 2000 Series
Dimensions
66 mm L x 40 mm W x 125.5 H
Pressure, Operating
1 MPa
Proof Pressure
1.5 MPa
Size, Port
1⁄4
Temperature, Ambient
0 to +60 °C
Thread Type
NPT
Operating Pressure Range
27 to 145 PSI
Allowable Voltage Fluctuation
–15% to +10% of Rated Voltage
Ambient And Fluid Temperature
32°-140°F
1. Use clean air.
1. Do not use valves in atmospheres of corro-
1. Install air filters.
2. Install an after-cooler, air dryer or water sepa-
2. Do not use in an explosive atmosphere.
3. Do not use in locations subject to vibration or
4. A protective cover, etc., should be used to
5. Shield valves from radiated heat generated
6. Employ suitable protective measures in loca-
7. In a dusty environment or when valve switch-
Do not use compressed air which contains chemicals, synthetic
oils containing organic solvents, salts or corrosive gases, etc.,
as this can cause damage or malfunction.
Install air filters close to valves at their upstream side. A filtra-
tion degree of 5µm or less should be selected.
rator, etc.
Air that includes excessive drainage may cause malfunction of
valves and other pneumatic equipment. To prevent this, install
an after-cooler, air dryer or water separator, etc.
sive gases, chemicals, salt water, water or
steam, or where there is direct contact with
any of these.
impact.
shield valves from direct sunlight.
by nearby heat sources.
tions where there is contact with water drop-
lets, oil or welding spatter, etc.
ing noise is intrusive, take measures for the
prevention of dust entry and for noise reduc-
tion, such as mounting a silencer on the R
port.
Caution
Warning
Warning
Operating Environment
AV2000/3000/4000/5000
Specific Product Precautions 3
Be sure to read before handling.
Refer to page 7 for safety instructions.
Air Supply
1. Drainage removal
Choke flow: when (P
Subsonic flow: when (P
Note) Formulas above apply to compressed air only. Use conven-
1. Perform maintenance procedures as shown
2. Equipment removal and supply/exhaust of
3. Low frequency operation
4. Manual override operation
How to Find the Flow Rate
Remove drainage from air filters regularly. (Refer to specifica-
tions.)
in the instruction manual.
If handled improperly, malfunction or damage of machinery or
equipment may occur.
compressed air
When equipment is removed, first confirm that measures are in
place to prevent dropping of work pieces and run-away of
equipment, etc. Then cut the supply pressure and power, and
exhaust all compressed air from the system using its residual
pressure release function.
Valves should be switched at least once every 30 days to pre-
vent malfunction. (Use caution regarding the air supply.)
When the manual override is operated, connected equipment
will be actuated. Confirm safety before operating.
Warning
Caution
tional formulas for water and steam.
Q = 120 x S x (P
Q = 240 x S x (P
Q : Air flow rate [
S : Effective area (mm²)
P
P
t : Air temperature
1
2
: Upstream pressure [MPa]
: Downstream pressure [MPa]
2
+ 0.1)/(P
1
2
1
Maintenance
+ 0.1) x —
+ 0.1)/(P
– P
2
)(P
l
1
/min (ANR)]
+ 0.1) ≤ 0.5
2
1
+ 0.1) x —
273 + t
+ 0.1) > 0.5
293
( at air temperature of 20°C )
273 + t
293
10