S18SP6FF50 W/30 BANNER ENGINEERING, S18SP6FF50 W/30 Datasheet - Page 2

no-image

S18SP6FF50 W/30

Manufacturer Part Number
S18SP6FF50 W/30
Description
EZ Beam S18; Fixed range 50mm; 10-30vdc; PNP; w/30 (9m cable)
Manufacturer
BANNER ENGINEERING
Datasheet
Supply Voltage and Current (exclusive of load current): 10 to 30V dc (10% max.
Supply Protection Circuitry
Output Configuration
Output Rating
Output Protection Circuitry
Output Response Time
Emitters, Non-Polarized Retro, Diffuse: 25 mA
Receivers: 20 mA
Polarized Retroreflective: 30 mA
Fixed-Field: 35 mA
Protected against reverse polarity and transient voltages
SPDT solid-state dc switch; Choose NPN (current sinking) or PNP (current
sourcing) models
Light Operate: N.O. output conducts when sensor sees its own (or the
Dark Operate: N.C. output conducts when the sensor sees dark; the N.C.
150 mA maximum (each) in standard hookup. When wired for alarm output, the
total load may not exceed 150 mA.
OFF-state leakage current: < 1 microamp @ 30V dc
ON-state saturation voltage: < 1V at 10 mA dc; < 1.5V at 150 mA dc
Protected against false pulse on power-up and continuous overload or short
circuit of outputs
Opposed mode: 3 ms ON, 1.5 ms OFF
Retro, Fixed-Field and Diffuse: 3 ms ON and OFF
ripple); supply current (exclusive of load current):
NOTE: 100 ms delay on power-up; outputs do not conduct during this time.
Right-angle
Euro-style
Euro-style
Straight
4-pin
4-pin
Style
S18 Sensors – dc-Voltage Series
emitter’s) modulated light
(normally closed) output may be wired as a normally open
marginal signal alarm output, depending upon hookup to power
supply (U.S. patent 5087838)
MQDC-406
MQDC-415
MQDC-430
MQDC-406RA
MQDC-415RA
MQDC-430RA
Model
2 m (6.5')
2 m (6.5')
5 m (15')
9 m (30')
5 m (15')
9 m (30')
Length
Quick-Disconnect (QD) Cables
Specifications
Repeatability
Indicators
Construction
Environmental Rating
Connections
Operating Conditions
Vibration and Mechanical Shock
Certifications
PBT polyester housing; polycarbonate (opposed mode) or acrylic lens
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
2 m (6.5') or 9 m (30') attached cable, or 4-pin Euro-style quick-disconnect
fitting
All models meet Mil. Std. 202F requirements. Method 201A (Vibration;
frequency 10 to 60 Hz, max., double amplitude 0.06" acceleration 10G).
Method 213B conditions H&I (Shock: 75G with unit operating; 100G for
non-operation)
Opposed mode: 375 µs
Retro, Fixed-Field and Diffuse: 750 µs
Repeatability and response are independent of signal strength.
Two LEDs (Green and Yellow)
Green ON steady: power to sensor is ON
Green flashing: output is overloaded
Yellow ON steady: N.O. output is conducting
Yellow flashing: excess gain marginal (1 to 1.5x) in light condition
Temperature: -40° to +70°C (-40° to +158°F)
Maximum relative humidity: 90% at 50°C (non-condensing)
ø 15 mm
M12 x 1
Dimensions
(0.6")
44 mm max.
38 mm max.
(1.7")
(1.5")
38 mm max.
(1.5")
M12 x 1
ø 15 mm
(0.6")
LISTED
R
Brown Wire
Black Wire
Pin-Out
Blue Wire
White Wire

Related parts for S18SP6FF50 W/30