HSC123.4 TDK Corporation, HSC123.4 Datasheet - Page 2

no-image

HSC123.4

Manufacturer Part Number
HSC123.4
Description
Power Supply, Single Output; 12 V; 3.4 A; 100/120/220/240 VAC; 47 to 63 Hz
Manufacturer
TDK Corporation
Type
Commercialr
Datasheet

Specifications of HSC123.4

Application
Low noise applications
Brand/series
H Series
Configuration
Open-Frame
Current, Rating
3.4 A
Frequency
47 to 63 Hz
Load Regulation
±0.05% @ 50% Load Change
Mounting Type
Panel
Number Of Outputs
1
Operation
Linear
Output
12 VDC @ 3.4 A
Power, Output
40.8 W
Primary Type
AC-DC
Regulation, Line
±0.05% @ 10% Line Change
Response Time
50 μs
Special Features
Remote Sense
Standards
UL Listed, CE and CSA Certified
Temperature Coefficient
±0.01 %⁄°C
Temperature, Operating
0 to +70 °C
Voltage, Input
100, 120, 220, 230, 240 VAC
Voltage, Output
12 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
H F e a t u r e s a n d B e n e f i t s
Feature
S p e c i f i c a t i o n s
ITEMS
AC Input
Efficiency
Transient Response
EMI
Output Adjustment
Remote Sense
Line Regulation
Load Regulation
Ripple and Noise
Overcurrent Protection
Overvoltage Protection
Cooling
Operating Temp. Range
Storage Temperature
Temperature coefficient
Humidity
Leakage Current
Vibration
Shock
Safety Agency Approval
Size
Warranty
Note: See Installation Manual for full details, test methods of parameters and application notes
Industry standard footprint
Low Output Ripple
Tight regulation
Operation up to 70C Ambients
uA
°C
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
On all single output models, HDC12 & HDC15, and output 1 of triple output models
100/120/220/230/240VAC, 47-63Hz (derate by 10% for 50Hz operation)
Standard on 5V outputs set at 6.2V ±0.4V OVP12 module sold separately
Foldback with automatic recovery (Contact factory before adjusting)
±5% for all outputs (except outputs 2 & 3 on triple output models)
0 to +70°C, derate 3%/°C above 50°C
Benefit
for other outputs (see model selector)
Test & Measurement
Low noise applications
Light Industrial
K e y M a r k e t S e g m e n t s & A p p l i c a t i o n s
UL60950-1, EN60950-1, CE Mark
Availability to second source
Reduced system interference
Better performance in sensitive equipment
Easier system integration
5V: 45%, 12/15V: 55%, 24V: 60%
FCC Class B, VDE0871 Level B
±0.05% for 50% load change
5 - 95% RH (non condensing)
±0.05% for 10% line change
MIL-STD-810C, Method 514
MIL-STD-810C, Method 516
Low Output Ripple
Single and Multiple Outputs
Excellent Line & Load Regulation
Worldwide Voltage Taps
Please see outline drawings
50us for 50% load change
Low Cost Linear Power Supplies
Convection or forced air
<3mV peak to peak
±0.01% per °C
-55 to +85°C
Two years
H Series
<50uA
Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
37