E2E2-X5Y1-US Omron Automation, E2E2-X5Y1-US Datasheet - Page 2

no-image

E2E2-X5Y1-US

Manufacturer Part Number
E2E2-X5Y1-US
Description
Sensor; Inductive Sensing Mode; M18; 5 mm; 24 to 240 VAC; 25 Hz; -40 to degC
Manufacturer
Omron Automation
Type
Inductiver
Datasheet

Specifications of E2E2-X5Y1-US

Body Style
Cylindrical
Current, Leakage
1.7 mA (Max.)
Current, Switching
300 mA
Frequency, Operating
50⁄60 Hz
Frequency, Switching
25 Hz
Function
Proximity
Indicator
Red LED (Operation Indicator)
Ip Rating
IP67
Material, Housing
Thick Nickel Plated Brass
Mounting Type
M18 Threaded
Output
NO
Primary Type
Proximity
Range, Measurement
5 mm
Standards
UL Recognized, CSA Certified, CE Marked
Technology
Inductive
Temperature Range
-40 to +85 °C
Termination
Pre-Wired
Voltage, Supply
240 VAC
Voltage, Switching
3 V
Supply Voltage Range
10-55 VDC or 20-264 VAC, 50/60 Hz (Model Dependant)
Load Rating
200 mA (DC) or 5-200 mA/5-300 mA (AC) (Model Dependant)
Approvals
CE, UL, CSA (Model Dependant)
Lead Free Status / Rohs Status
RoHS Compliant part
Accessories (Order Separately)
Mounting Brackets
Protective Covers
Sputter Protective Covers
Ratings and Specifications
E2E2-X@D@ DC 2-Wire Models
*1. Use the E2E2 within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
Item
Sensing distance
Set distance *1
Differential travel
Sensing object
Standard sensing object
Response frequency *2
Power supply voltage
(operating voltage range)
Leakage current
Control
output
Indicators
Operation mode
(with sensing object ap-
proaching)
Protection circuits
Ambient temperature
Ambient humidity
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
(destruction)
Shock resistance
(destruction)
Degree of protection
Connection method
Weight (packed state)
Materi-
als
Accessories
a set distance of half the sensing distance.
Switching
capacity
Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m)
Case
Sensing surface PBT
Clamping nuts
Toothed washer Zinc-plated iron
Shielding
Model
Size
3 mm±10%
0 to 2.4 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on
page 5.)
Iron,
12 × 12 × 1 mm
1 kHz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
3 to 100 mA
D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
D1 Models: NO
D2 Models: NC
Surge absorber, Load short-circuit protection
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
1,000 m/s
IEC IP67, in-house standard for oil resistance
Pre-wired Models (Standard cable length: 2 m)
Approx. 65 g
Brass
Nickel-plated brass
Instruction sheet
E2E2-X3D@
Shielded
2
10 times each in X, Y, and Z directions
M12
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
8 mm±10%
0 to 6.4 mm
Iron,
30 × 30 × 1 mm
800 Hz
E2E2-X8MD@
Unshielded
7 mm±10%
0 to 5.6 mm
Iron,
18 × 18 × 1 mm
500 Hz
Approx. 150 g
E2E2-X7D@
Shielded
M18
14 mm±10%
0 to 11.2 mm
Iron,
30 × 30 × 1 mm
400 Hz
E2E2-X14MD@
Unshielded
10 mm±10%
0 to 8 mm
Iron,
30 × 30 × 1 mm
Approx. 210 g
E2E2-X10D@
Shielded
M30
E2E2-X20MD@
20 mm±10%
0 to 16 mm
Iron,
54 × 54 × 1 mm
100 Hz
Unshielded
E2E2
2

Related parts for E2E2-X5Y1-US