VNH2SP30 STMicroelectronics, VNH2SP30 Datasheet - Page 8

no-image

VNH2SP30

Manufacturer Part Number
VNH2SP30
Description
Motor / Motion / Ignition Controllers & Drivers VIPOWER
Manufacturer
STMicroelectronics
Type
Half Bridge Motor Driverr
Datasheets

Specifications of VNH2SP30

Operating Supply Voltage
5.5 V to 16 V
Supply Current
10 mA
Mounting Style
SMD/SMT
Package / Case
MultiPowerSO-30
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VNH2SP30
Manufacturer:
STM
Quantity:
1 831
Part Number:
VNH2SP30
Manufacturer:
ST
0
Part Number:
VNH2SP30
Manufacturer:
ST
Quantity:
20 000
Part Number:
VNH2SP30-E
Manufacturer:
ST
0
Part Number:
VNH2SP30-E
Manufacturer:
ST
Quantity:
20 000
Part Number:
VNH2SP30E
Manufacturer:
ST
0
Part Number:
VNH2SP30TR-E
Manufacturer:
ST
Quantity:
2 100
Part Number:
VNH2SP30TR-E
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
VNH2SP30TR-E
Quantity:
2 000
VNH2SP30-E
Figure 5. Typical Application Circuit For Dc To 20khz PWM OperationShort Circuit Protection
In case of a fault condition the DIAG
considered as an output pin by the device.
The fault conditions are:
- overtemperature on one or both high sides (for example
if a short to ground occurs as it could be the case
described in line 1 and 2 in the table below);
- short to battery condition on the output (saturation
Possible origins of fault conditions may be:
OUT
detection on high side A.
OUT
saturation detection.
When a fault condition is detected, the user can know
Table 15. Truth Table In Fault Conditions (Detected On OUT
8/26
detection on the Low-Side Power MOSFET).
IN
X
X
X
1
1
0
0
A
A
A
is shorted to V
is shorted to ground ---> overtemperature
Reg 5V
C
IN
X
1
0
1
0
1
0
33nF
B
CC
DIAG
10K
1K
1K
1K
3.3K
1.5K
---> Low-Side Power MOSFET
A
/EN
DIAG
PWM
CS
IN
A
A
+ 5V
0
0
0
0
0
0
0
A
Fault Information
/EN
A
GND
LS
HS
A
X
A
/EN
V
A
OUT
CC
DIAG
X
A
100K
pin is
1
1
1
1
0
1
1
B
/EN
G
B
D
S
M
V
CC
which power element is in fault by monitoring the IN
IN
In any case, when a fault is detected, the faulty leg of the
bridge is latched off. To turn-on the respective output
(OUT
level.
B
b) N MOSFET
, DIAG
X
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OUT
) again, the input signal must rise from low to high
OUT
Protection Action
A
A
A
B
/EN
)
HS
LS
A
B
B
and DIAG
DIAG
GND
B
IN
/EN
B
OPEN
B
OUT
B
B
H
H
H
L
L
L
/EN
B
B
+5V
> 50uF
pins.
3.3K
1K
1K
High Imp.
High Imp.
High Imp.
High Imp.
High Imp.
I
I
OUTB
OUTB
CS
/K
/K
A
,

Related parts for VNH2SP30