CS5461A-IS Cirrus Logic Inc, CS5461A-IS Datasheet - Page 24

Other Power Management Single-Phase Bi-Dir Power/Energy IC

CS5461A-IS

Manufacturer Part Number
CS5461A-IS
Description
Other Power Management Single-Phase Bi-Dir Power/Energy IC
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS5461A-IS

Mounting Style
SMD/SMT
Package / Case
SOIC-8
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5461A-ISZ
Manufacturer:
CIRRUS
Quantity:
114
Part Number:
CS5461A-ISZ
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
CS5461A-ISZ
Quantity:
267
Part Number:
CS5461A-ISZR
Manufacturer:
CIRRUS
Quantity:
20 000
5.14.5 Register Read/Write
The Read/Write informs the command decoder that a register access is required. During a read operation, the ad-
dressed register is loaded into an output buffer and clocked out by SCLK. During a write operation, the data is
clocked into an input buffer and transferred to the addressed register upon completion of the 24
24
B7
0
W/R
RA[4:0]
Address
Note: For proper operation, do not attempt to write to unspecified registers.
W/R
B6
0
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
RA4
B5
0 = Read
1 = Write
Write/Read control
Register address bits (bits 5 through 1) of the read/write command.
RA[4:0]
00000
00001
00010
00011
00100
00101
00110
00111
01000
01001
01010
01011
01100
01110
10000
10001
10010
10011
10100
10101
10110
11001
11010
11011
11100
11101
11110
11111
01111
10111
11000
RA3
B4
RA2
B3
Name
Config
I
I
V
V
Cycle Count
PulseRateE
I
V
P
P
I
V
P
Status
I
V
PulseRateE
T
SYS
PW
PulseWidth
VSAG
VSAG
LoadIntv
Mask
LoadMin
Ctrl
T
T
S
DCoff
gn
RMS
ACoff
Gain
off
DCoff
gn
Active
RMS
off
ACoff
Gain
RA1
B2
Duration
Level
RA0
1,2
3
B1
Description
Configuration
Current DC Offset
Current Gain
Voltage DC Offset
Voltage Gain
Number of A/D conversions used in one computation cycle (N)).
Sets the E1 and E2 energy-to-frequency output pulse rate.
Instantaneous Current
Instantaneous Voltage
Instantaneous Power
Active (Real) Power
RMS Current
RMS Voltage
Power Offset
Status
Current AC (RMS) Offset
Voltage AC (RMS) Offset
Sets the E3 energy-to-frequency output pulse rate.
Temperature
System Gain
Pulse width register for mechanical counter output mode
Pulse width register for E3 energy pulse output
Voltage Sag Duration
Voltage Sag Level Threshold
No load threshold interval (detection window)
Interrupt Mask
No Load Threshold
Control
Temperature Sensor Gain
Temperature Sensor Offset
Apparent Power
B0
0
th
SCLK.
CS5461A
DS661F2

Related parts for CS5461A-IS