LG01-2000A005 SENSIRION, LG01-2000A005 Datasheet
LG01-2000A005
Specifications of LG01-2000A005
Related parts for LG01-2000A005
LG01-2000A005 Summary of contents
Page 1
... Shift of switching point if not mounted in normal position (which is horizontal flow channel) but with vertical flow channel. b www.sensirion.com capillary. unless otherwise noted) abs LG01-2000A005 LG01-2000A090 50 220 0.25 4.5 ±10 ±10 ±5 +2 +14 50 120 +10…+50 -10…+60 LG01-2000A090 2 May_ 2011 _ V1.3 of the LG01 Liquid Flow Switch is ml/min ml/min % ± °C °C LG01-2000A005 5.5 LG01-2000Axxx models. 1/4 ...
Page 2
... This can cause it to break! Test for leakage every time after new connections are made. Inside the LG01 flow sensors a highly sensitive microsensor-chip is mounted on the outside of a straight glass capillary and allows to measure the flow through the wall (US Patent 6,813,944 B2) using a thermal principle. ...
Page 3
... Ordering Information The LG01 flow sensors can be ordered for OEM volume applications. Product LG01-2000A090 LG01-2000A005 LG01 Connectivity Kit 7.2 ESD Precautions The inherent design of this component causes sensitive to electrostatic discharge (ESD). To prevent ESD- induced damage and/or degradation, take customary and statutory ESD precautions when handling this product. ...
Page 4
... Teflon® and Tefzel® are registered trademarks of DuPont Corporation Duran® trademark of the SCHOTT-Group 7.4 RoHS and WEEE Statement The LG01 product family complies with requirements of the following directives: EU Directive 2002/96/EC on waste electrical and electronic equipment(WEEE), OJ13.02.2003; esp. its Article 6 (1) with Annex II. ...