Specifications of SMART 2200NET

Power Rating
2200 VA
Output Voltage Rating
120 V
Number Of Outlets
6
Interface Port
DB9 / Contact Closure
Runtime (full Load)
11 min
Runtime (half Load)
27 min
Topology
Line Interactive
Tower / Rackmount
Tower
Application
Ideal for the protection of communication equipment including: routers, hubs, switches, IP-PBX, Traditional PBX and key⁄hybrid Telephone Systems. Also ideal for the protection of data processing equipment such as fileservers, workstations and other sensit
Approvals
UL Listed, CE Approved
Brand/series
SmartPro®
Capacity
2200 VA
Color
Gray
Communication
DB9, RS232
Connection, Input
NEMA 5-15P
Dimensions
41.9cmH×22.9cmW×31.1cmD
Input Type
NEMA 5-15P
Length, Cord
8 ft.
Mounting Type
Rack/Tower
Operation
Line-Interactive
Output Type
(6) NEMA 5-15R
Power, Rating
1700 W
Receptacle Style
6 NEMA 5-15R
Time, Backup
11 min.
Voltage, Input
120 V
Voltage, Output
120 VAC
Voltage, Supply
1700/2200 W/VA
Weight
36.3 kg
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
AC suppression
response time
PHYSICAL
Installation form factors
supported with included
accessories
Primary form factor
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / inches)
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / cm)
UPS / Power Module
weight (lbs)
UPS / Power Module
weight (kg)
UPS Shipping
dimensions (height x
width x depth / inches)
UPS Shipping
dimensions (height x
width x depth / cm)
Shipping weight (lbs)
Shipping weight (kg)
UPS housing material
ENVIRONMENTAL
Operating Temperature
Range
Storage Temperature
Range
Relative Humidity
AC mode BTU / hr. (full
load)
Battery mode BTU / hr.
(full load)
COMMUNICATIONS
Communications
interface
Network monitoring
port description
PowerAlert software
Communications cable
LINE / BATTERY TRANSFER
Transfer time
Instantaneous
Tower
Tower
17 x 9 x 12.5
43.2 x 22.9 x 31.8
80
36.3
22.2 x 12.8 x 16.5
56.5 x 32.4 x 41.9
87
39.5
Polycarbonate
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
58.4
863.7
DB9 Serial; Contact closure
Supports detailed monitoring of UPS and site power conditions; contact closure communications via two
additional DB9 ports (3 total)
Included
3 DB9 cables included
2-4 milliseconds