170 Series True-rms DMMs
Extended Specifications
©2000 Fluke Corporation
Rev. A-11/2000
General Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative
humidity of 0 % to 75 %. Accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] )
Maximum voltage between any
terminal and earth ground
Surge Protection
Fuse for mA inputs
Fuse for A input
Display
Altitude
Temperature
Temperature coefficient
Electromagnetic Compatibility
(EN 61326-1:1997)
Relative Humidity
Relative Humidity in
50 M
Battery Life
Size, with Holster (H x W x L)
Weight
Safety Compliances
Certifications
Range
1000V DC or AC RMS
8 kV peak per IEC 61010
440 mA, 1000 V FAST Fuse
11A, 1000V FAST Fuse
Digital: 6,000 counts, updates 4/sec
Bar Graph: 33 segments, updates 40/sec
Frequency: 9,999 counts
Capacitance: 9,999 counts
Operating: 2000 m; Storage: 12000 m
Operating: -10 °C to +50 °C
Storage: -30 °C to +60 °C
0.1 X (specified accuracy / °C)
(< 18 °C or > 28 °C)
In an RF field of 3 V/M, accuracy = specified accuracy except in
temperature: specified accuracy ± 5 °C, ± 9 °F
0 % to 90 % @ 0 °C to 35 °C;
0 % to 70 % @ 36 °C to 50 °C
0 % to 80 % @ 0°C to 35°C;
0 % to 70 % @ 36 °C to 50 °C
Alkaline: ~200 hrs typical
4.3 cm x 9 cm x 18.5 cm
420g
ANSI/ISA S82.02.01, CSA C22.2-1010.1, IEC 61010 to 1000 V Overvoltage
Category III, 600 V Overvoltage Category IV
CSA, TÜV (EN61010),
Australian