FLUKE-8846A NIST W/DATA Fluke, FLUKE-8846A NIST W/DATA Datasheet - Page 12

no-image

FLUKE-8846A NIST W/DATA

Manufacturer Part Number
FLUKE-8846A NIST W/DATA
Description
Digital Multimeters 6.5 BENCH DMM NIST W/DATA
Manufacturer
Fluke

Specifications of FLUKE-8846A NIST W/DATA

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
2132558
Additional Errors
Continuity
Continuity Threshold ..................................................Selectable between 1 Ω and 1000 Ω
Test Current...................................................................1 mA
Response Time..............................................................300 samples/sec with audible tone
Accuracy is given as ± (% measurements + % of range)
Diode Test
Test Current...................................................................100 μA or 1 mA
Response Time..............................................................300 samples/sec with audible tone.
Accuracy is given as ± (% measurements + % of range)
Measurement Rates (IEEE488[4])
1000.0 Ω
5.0000 V
10.0000 V
DC Volts, DC Current, and
Resistance
AC Voltage and AC Current
Frequency and Period
C
a
[1]
[2]
[3]
[4]
p
a
Range
Range
i c
a t
Typical measurement rates with auto-zero off, delay = 0, display off, auto range off and math off.
Maximum measurement rates for 0.01 % of ac step. When dc input varies, additional settling delay is required.
For remote operation or external trigger using default settling delay
Speeds available in OutG SW 1.0.700.18 or higher. Note that the measurements rates for RS232 can vary depending on the
baud rate chosen. If the baud rate selected is 115,200, the maximum measurement rate is 711 measurement/s. The LAN bus
has a maximum measurement rate of 963 measurement/s.
n
Digits
e c
Function
6
6
5
5
4 ½
½
½
½
½
0.002 + 0.002
0.002 + 0.001
0.002 + 0.01
(23 ±1 °C)
(23 ±1 °C)
24 Hour
24 Hour
[2]
Digits
NPLC
6
0.02
1
0
1
1
0
1
2 .
0
2 /
0
0.008 + 0.002
0.008 + 0.002
0.008 + 0.02
(23 ±5 °C)
(23 ±5 °C)
90 Days
90 Days
0.02 NPLC
100 NPLC
Setting
0.2 NPLC
10 NPLC
200 Hz
100 ms
1 NPLC
10 ms
20 Hz
3 Hz
Additional NPLC Noise Error
1 s
[3]
Integration Time
0.01 + 0.02
0.01 + 0.002
0.01 + 0.002
60 Hz (50 Hz)
167 (200) ms
0
0
16.7 (20) ms
(23 ±5 °C)
(23 ±5 °C)
0.6 °C
0 .
1 .
0
0
1.67 (2) s
1 Year
1 Year
3
2
3.3 ms
500 us
C °
C °
Fluke. Keeping your world
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
C °
C °
up and running.
Outside 18 to 28 °C
Outside 18 to 28 °C
0.001 + 0.002
0.001 + 0.002
0.001 + 0.002
Coefficient/ °C
Coefficient/ °C
8845A
0.6 (0.5)
Temperature
Temperature
Measurements/Second
60 (50)
6 (5)
0.47
1.64
270
995
4.5
9.8
N
80
1
A
®
8846A
0.6 (0.5)
60 (50)
6 (5)
0.47
1.64
270
995
4.5
9.8
80
1
2
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2006-2008 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 2/2008 2748044 D-EN-N Rev B