AC71B Amprobe, AC71B Datasheet - Page 2

Clamp Multimeters & Accessories AUTOMATIC 600A CLAMPMETER W/AUTOTEC

AC71B

Manufacturer Part Number
AC71B
Description
Clamp Multimeters & Accessories AUTOMATIC 600A CLAMPMETER W/AUTOTEC
Manufacturer
Amprobe
Datasheet

Specifications of AC71B

Display Count
6000
Maximum Ac Current
600 A
True Rms
No
Voltage
750 VAC/1000 VDC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
2727872
AC71B Automatic AC Clamp Multimeter
General Specifications
Display
Measuring Rate
Overrange Display
Automatic Power Off Time
Power
Battery Life
Environmental
Operating Temperature
Storage Temperature
Altitude
Conductor Size
Max. Operation Time
Shock Vibration
Agency Approvals
Safety
EMC
Amprobe® Test Tools
6000 digit large scale liquid crystal display (LCD)
5 times per second
OL is displayed
Approximately 30 minutes after power on Low Battery Indication The battery symbol is displayed when
the battery voltage drops below the operating level for accurate results.
Single standard 9 V battery, NEDA160A
250 hours with an alkaline 9 V battery
Indoor use
0 °C to 30 °C at ² 80 % R.H.
30 °C to 40 °C at ² 75 % R.H.
40 °C to 50 °C at ² 45 % R.H.
-20 °C to 60 °C at 0 to 80 % R.H. (battery removed)
2000 m (6562 ft)
32 mm diameter (1.3 in)
Delay Time = 30s for input ² 30 V
Sinusoidal vibration per MIL-PRF-28800F (5 to 55 Hz, 3 G maximum)
CE, cCSAus
Conforms to EN61010-1:2001; CAT II 1000 V, CAT III 600 V, Pollution degree 2, Class 2
Conforms to EN61326-1.
www.Amprobe.com
Data Sheet