MAX3050ASA+T Maxim Integrated Products, MAX3050ASA+T Datasheet - Page 10

IC TXRX CAN 2MBPS 8-SOIC

MAX3050ASA+T

Manufacturer Part Number
MAX3050ASA+T
Description
IC TXRX CAN 2MBPS 8-SOIC
Manufacturer
Maxim Integrated Products
Type
Transceiverr
Datasheet

Specifications of MAX3050ASA+T

Number Of Drivers/receivers
1/1
Protocol
CAN
Voltage - Supply
4.5 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
To manage power consumption, AutoShutdown puts
the device into shutdown mode after the device has
been inactive for a period of time. The value of an
external capacitor (C
mines the threshold of inactivity time, after which the
AutoShutdown triggers. Floating SHDN allows the
MAX3050 to automatically change from active mode to
shutdown.
Use a 100nF capacitor as C
old of 20ms. Change the capacitor value according to
the following equation to change the threshold time
period.
V
than 2V in the Electrical Characteristics table. Drive
SHDN high to turn the MAX3050 on and disable
AutoShutdown.
When the MAX3050 is in shutdown mode, only the
wake-up comparator is active, and normal bus commu-
nication is ignored. The remote master of the CAN sys-
tem wakes up the MAX3050 with a signal greater than
9V on CANH. Internal circuitry in the MAX3050 puts the
device in normal operation by driving SHDN high.
The MAX3057 does not have the AutoShutdown feature.
The MAX3050/MAX3057 have several features that pro-
tect them from damage. Thermal shutdown switches off
the device and puts CANH and CANL into high imped-
ance if the junction temperature exceeds +160°C.
Thermal protection is needed particularly when a bus
line is short circuited. The hysteresis for the thermal
shutdown is approximately 20°C.
Additionally, a current-limiting circuit protects the trans-
mitter output stage against short-circuits to positive and
negative battery voltage. Although the power dissipa-
tion increases during this fault condition, this feature
prevents destruction of the transmitter output stage.
±80V Fault-Protected, 2Mbps, Low Supply
Current CAN Transceivers
10
SHDN
______________________________________________________________________________________
is the threshold of SHDN guaranteed to be less
C
SHDN
(
nF
)
SHDN
=
AutoShutdown (MAX3050)
(
0 02
Driver Output Protection
V
.
CC
) connected to SHDN deter-
×
SHDN
time s
V
SHDN
(
µ
for a typical thresh-
)
)
Figure 5. FFT Dominant Bus at 2Mbps
Figure 6. FFT Recessive Bus at 2Mbps
Figure 7. FFT Dominant Bus at 500kbps
CANH - CANL
1V/div
FFT
500mV/div
CANH - CANL
1V/div
FFT
200mV/div
CANH - CANL
1V/div
FFT
500mV/div

Related parts for MAX3050ASA+T