MAX3380ECUP Maxim Integrated Products, MAX3380ECUP Datasheet - Page 7

LINE TRANSEIVER CMOS 2PIN TSSOP

MAX3380ECUP

Manufacturer Part Number
MAX3380ECUP
Description
LINE TRANSEIVER CMOS 2PIN TSSOP
Manufacturer
Maxim Integrated Products
Type
Transceiverr
Datasheet

Specifications of MAX3380ECUP

Number Of Drivers/receivers
2/2
Protocol
RS232
Voltage - Supply
2.4 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
20-TSSOP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
Q1782234

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX3380ECUP
Manufacturer:
MAXIM
Quantity:
5
Part Number:
MAX3380ECUP
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX3380ECUP+
Manufacturer:
Maxim
Quantity:
1 998
Part Number:
MAX3380ECUP+T
Manufacturer:
MAXIM
Quantity:
5
Part Number:
MAX3380ECUP+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
The MAX3380E/MAX3381E include a switchover circuit
between RS-232-compliant and RS-232-compatible
modes that has approximately 400mV of hysteresis
around the switchover point. The hysteresis is shown in
Figure 1. This large hysteresis helps to avoid mode
change under battery or power-supply bounce.
Under a decaying V
an output voltage of ±5.5V with a V
between +3.1V and +5.5V. When V
switchover point of +3.1V, the charge pump switches
into RS-232-compatible mode generating ±4V.
When V
output voltage of ±4.0V, while V
and +3.5V. When V
age of +3.5V, the charge pump switches to RS-232-
compliant mode to generate an output voltage of ±5.5V.
The transmitters are inverting level translators that con-
vert CMOS-logic levels to RS-232-compatible levels.
The MAX3380E/MAX3381E will automatically reduce
the RS-232-compliant levels from ±5.5V to ±3.7V when
V
els are RS-232-compatible and reduce supply current
requirements that help preserve the battery. Built-in
hysteresis of approximately 400mV for V
that the RS-232 output levels do not change if V
noisy or has a sudden current draw causing the supply
voltage to drop slightly. The outputs will return to RS-
232-compliant levels (±5.5V) when V
approximately +3.5V.
Figure 1. V+ Switchover for Changing Vcc
CC
+2.35V to +5.5V, 1µA, 2Tx/2Rx RS-232 Transceivers
falls below approximately +3.1V. The reduced lev-
2V/div
2V/div
CC
V
CC
V+
is rising, the charge pump will generate an
with ±15kV ESD-Protected I/O and Logic Pins
_______________________________________________________________________________________
CC
CC
Voltage Generation in the
, the charge pump will generate
rises above the switchover volt-
20ms/div
RS-232 Transmitters
Switchover Region
CC
CC
is between +2.5V
CC
drops below the
CC
input range
rises above
CC
+4.5V
+2.5V
+5.8V
+4.4V
ensures
CC
is
The MAX3380E/MAX3381E transmitters guarantee a data
rate of 460kbps/250kbps, respectively, with worst-case
loads of 3kΩ in parallel with 1000pF. Transmitters can be
paralleled to drive multiple receivers.
When FORCEOFF is driven to ground, the transmitters
are disabled and the outputs go into high impedance;
receivers remain active. When the AutoShutdown Plus
circuitry senses that all receiver and transmitter inputs
are inactive for more than 30s, the transmitters are dis-
abled and the outputs go into a high-impedance state,
and the receivers remain active. When the power is off,
the MAX3380E/MAX3381E permit the outputs to be dri-
ven up to ±12V.
The transmitter inputs have a 400kΩ active positive
feedback resistor. They will retain a valid logic level if
the driving signal is removed or goes high impedance.
Connect unused transmitter inputs to V
The receivers convert RS-232 signals to logic levels
referred to V
(Table 1).
The MAX3380E/MAX3381E achieve a 1µA supply current
with Maxim’s AutoShutdown Plus feature, which operates
when FORCEOFF is high and FORCEON is low. When
these devices do not sense a valid signal transition on
any receiver and transmitter input for 30s, the on-board
charge pumps are shut down, reducing supply current
to 1µA. This occurs if the RS-232 cable is disconnected
or if the connected peripheral transmitters are turned off,
and if the UART driving the transmitter inputs is inactive.
The system turns on again when a valid transition is
applied to any RS-232 receiver or transmitter input. As a
result, the system saves power without changes to the
existing BIOS or operating system.
Figures 2a and 2b show valid and invalid RS-232
receiver voltage levels. INVALID indicates the receiver
input’s condition, and is independent of the FORCEON
and FORCEOFF states. Figure 2 and Table 1 summa-
rize the MAX3380E/MAX3381E’s operating modes.
FORCEON and FORCEOFF override AutoShutdown
Plus circuitry. When neither control is asserted, the IC
selects between these states automatically based on
the last receiver or transmitter input edge received.
By connecting FORCEON to INVALID, the MAX3380E/
MAX3381E is shut down when no valid receiver level and
no receiver or transmitter edge is detected for 30s, and
wakes up when a receiver or transmitter edge is detect-
ed (Figure 2c).
L
. Both receivers are active in shutdown
AutoShutdown Plus Mode
RS-232 Receivers
CC
or ground.
7

Related parts for MAX3380ECUP