THB 6-2411 TRACOPOWER, THB 6-2411 Datasheet - Page 2

DC/DC CONVERTER, 5V, 6W

THB 6-2411

Manufacturer Part Number
THB 6-2411
Description
DC/DC CONVERTER, 5V, 6W
Manufacturer
TRACOPOWER
Datasheet

Specifications of THB 6-2411

Dc / Dc Converter O/p Type
Fixed
No. Of Outputs
1
Input Voltage
18V To 36V
Power Rating
6W
Output Voltage
5V
Output Current
1A
Approval Bodies
UL, EN, IEC
Supply Voltage
24V
Rohs Compliant
Yes
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Input Specifications
Input current at no load / full load
Start-up voltage /
under voltage shut down
Recommanded input fuse (slow blow)
Surge voltage (1 sec. max.)
Input filter
Output Specifications
Voltage set accuracy
Regulation
Minimum load
Ripple and noise (20 MHz bandwidth)
Transient Response (25% load step change)
Current limitation
Short circuit protection
Capacitive load
Isolation / Safety Standards
Isolation test voltage (flash tested 1 sec.)
I/O isolation voltage (50Hz, 60sec.)
Leakage current (at 240VAC, 60Hz)
I/O isolation capacity (at 100KHz, 1V)
I/O isolation resistance (at 500VDC)
Safety standards
Safety approvals (pending)
– Input variation Vin min. to Vin max.
– Load variation 25 – 100 %:
12 VDC output models:
24 Vin; 5 VDC model: 20 mA typ. / 280 mA typ.
48 Vin; 5 VDC model: 10 mA typ. / 140 mA typ.
12 Vin; 5 VDC model: 30 mA typ. / 570 mA typ.
5 VDC output models: 1000 µF max.
24 Vin; other models: 20 mA typ. / 315 mA typ.
48 Vin; other models: 10 mA typ. / 155 mA typ.
12 Vin; other models: 30 mA typ. / 640 mA typ.
single output models: 1.0 % max.
dual output models: 2.0 % max. balanced load
dual output models:
5 VDC models: 100 mVp-p max.
24 Vin models: 18 VDC / 16 VDC typ.
48 Vin models: 36 VDC / 34 VDC typ.
24 Vin models: 0.6 A
48 Vin models: 0.3 A
24 Vin models: 50 VDC max.
48 Vin models: 100 VDC max.
12 Vin models: 9 VDC / 8.5 VDC typ.
12 Vin models: 1.2 A
12 Vin models: 25 VDC max.
other models: 150 mVp-p max.
EN 55022 class A
±1.0 %
1.0 % max.
20 % of rated max. output current.
(Operation at lower load is safe but major
deviations to specified data may occur)
500 µs max.
>120 % Iout max.
indefinite (automatic recovery)
6000 Vpk
4000 VACrms
2 µA
7 pF typ.
>1000 Mohm
IEC/EN 60950-1, UL 60950-1
IEC/EN 60601-1, UL 60601-1
CB-report, CSA
470 µF max.
220 µF max. (each output)