ST72T631K4M1 STMicroelectronics, ST72T631K4M1 Datasheet - Page 81

no-image

ST72T631K4M1

Manufacturer Part Number
ST72T631K4M1
Description
Microcontrollers (MCU) OTP EPROM 16K USB/SC
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST72T631K4M1

Data Bus Width
8 bit
Program Memory Type
EPROM
Program Memory Size
16 KB
Data Ram Size
512 B
Interface Type
I2C, SCI, USB
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
19
Number Of Timers
2
Operating Supply Voltage
4 V to 5.5 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Package / Case
SO-34
Minimum Operating Temperature
0 C
On-chip Adc
8 bit
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST72T631K4M1
Quantity:
28
Part Number:
ST72T631K4M1
Manufacturer:
SIEMENS
Quantity:
5 510
Part Number:
ST72T631K4M1
Manufacturer:
ST
0
Part Number:
ST72T631K4M1
Manufacturer:
ST
Quantity:
20 000
Part Number:
ST72T631K4M1/L4M1
Manufacturer:
ST
0
I²C BUS INTERFACE (Cont’d)
I²C STATUS REGISTER 2 (SR2)
Read Only
Reset Value: 0000 0000 (00h)
Bits 7:5 = Reserved. Forced to 0 by hardware.
Bit 4 = AF Acknowledge failure .
This bit is set by hardware when no acknowledge
is returned. An interrupt is generated if ITE=1. It is
cleared by software reading SR2 register or by
hardware when the interface is disabled (PE=0).
The SCL line is not held low while AF=1.
0: No acknowledge failure
1: Acknowledge failure
Bit 3 = STOPF Stop detection (Slave mode).
This bit is set by hardware when a Stop condition
is detected on the bus after an acknowledge (if
ACK=1). An interrupt is generated if ITE=1. It is
cleared by software reading SR2 register or by
hardware when the interface is disabled (PE=0).
The SCL line is not held low while STOPF=1.
0: No Stop condition detected
1: Stop condition detected
Bit 2 = ARLO Arbitration lost .
This bit is set by hardware when the interface los-
7
0
0
0
AF
STOPF ARLO BERR GCAL
0
es the arbitration of the bus to another master. An
interrupt is generated if ITE=1. It is cleared by soft-
ware reading SR2 register or by hardware when
the interface is disabled (PE=0).
After an ARLO event the interface switches back
automatically to Slave mode (M/SL=0).
The SCL line is not held low while ARLO=1.
0: No arbitration lost detected
1: Arbitration lost detected
Bit 1 = BERR Bus error.
This bit is set by hardware when the interface de-
tects a misplaced Start or Stop condition. An inter-
rupt is generated if ITE=1. It is cleared by software
reading SR2 register or by hardware when the in-
terface is disabled (PE=0).
The SCL line is not held low while BERR=1.
0: No misplaced Start or Stop condition
1: Misplaced Start or Stop condition
Bit 0 = GCAL General Call (Slave mode).
This bit is set by hardware when a general call ad-
dress is detected on the bus while ENGC=1. It is
cleared by hardware detecting a Stop condition
(STOPF=1) or when the interface is disabled
(PE=0).
0: No general call address detected on bus
1: general call address detected on bus
ST7263
81/109