MXL1544CAI Maxim Integrated Products, MXL1544CAI Datasheet - Page 14

no-image

MXL1544CAI

Manufacturer Part Number
MXL1544CAI
Description
Buffers & Line Drivers 5V Multiprotocol Cable Terminator
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MXL1544CAI

Logic Family
MXL1544
Logic Type
Software Selectable Control Transceiver
Supply Voltage (max)
6 V
Supply Voltage (min)
- 0.3 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Package / Case
SSOP-28
Data Rate
2 Mbps
Interface
RS-232, RS-423, RS-449
Maximum Power Dissipation
889 mW
Minimum Operating Temperature
0 C
Output Current
- 50 mA to + 50 mA
Output Voltage
- 0.3 V to + 6.3 V
Supply Current
95 mA
Dc
02+
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MXL1544CAI
Manufacturer:
MAXIM
Quantity:
45
Company:
Part Number:
MXL1544CAI
Quantity:
445
Part Number:
MXL1544CAI+T
Manufacturer:
MAXIM
Quantity:
452
Part Number:
MXL1544CAI+T
Manufacturer:
MAXIM/美信
Quantity:
20 000
+5V Multiprotocol, Software-Selectable
Control Transceivers
Figure 14. V.11 Internal Resistance Networks
Figure 16 shows a port with one DB-25 connector that
can be configured for either DTE or DCE operation. The
configuration requires separate cables for proper sig-
nal routing in DTE or DCE operation. Figure 16 illus-
trates a DCE or DTE controller-selectable interface. The
DCE/DTE and INVERT inputs switch the port’s mode of
operation (Table 1).
The MXL1543 and MXL1544/MAX3175 can be connect-
ed for either DTE or DCE operation in one of two ways:
a dedicated DTE or DCE port with an appropriate gen-
der connector or a port with a connector that can be
configured for DTE or DCE operation by rerouting the
signals to the MXL1543 and MXL1544/MAX3175 using
14
A′
B′
C′
______________________________________________________________________________________
A
B
GND
S3
R8
5kΩ
30kΩ
30kΩ
R5
R4
10kΩ
R6
DTE vs. DCE Operation
R7
10kΩ
RECEIVER
MXL1544
MAX3175
a dedicated DTE cable or dedicated DCE cable. The
interface mode is selected by logic outputs from the
controller or from jumpers to either V
mode select pins. A dedicated DCE port using a DB-25
female connector is shown in Figure 17. Figure 18 illus-
trates a dedicated DTE port using a DB-25 male con-
nector.
Figure 15. V.28 Termination and Internal Resistance Network
A′
B′
C′
A
B
GND
S3
R8
5kΩ
30kΩ
30kΩ
R5
R4
10kΩ
10kΩ
R6
R7
CC
RECEIVER
MAX3175
MXL1544
or GND on the