ARF7429B ADEUNIS, ARF7429B Datasheet - Page 15

MODULE, ARF54, US

ARF7429B

Manufacturer Part Number
ARF7429B
Description
MODULE, ARF54, US
Manufacturer
ADEUNIS
Type
Modem Moduler
Datasheets

Specifications of ARF7429B

Modulation Type
FM
Data Rate Max
57.6Kbps
Sensitivity
-108dBm
Supply Voltage Range
3V To 3.6V
Supply Current
700mA
Features
Two-way Digital Link Over 6000m, Programmable Up To 57.6kbps Rough Data Rate
Rohs Compliant
Yes
Command mode
The command mode is used to read and update the modem configuration
registers using AT command.
N
The AT command can be locked using ATPWD command.
In command mode, the radio is inhibited (reception and transmission),
excepted when using test command.
Entering command mode :
sequence of 3 consecutive + characters is accepted only if no character have
been seen before and after the +++ sequence. Register (S214) defines the
silence duration.
Tips 1:
the +++ sequence using a text file (first create a text file containing only the
+++ characters, and then use in Hyperterm the command “Send text file” in
the “Transfer menu”)
Tips 2:
Exiting command mode
command
Ref. 08-07-V6-lmn
OTE
RXD
line
Idle line for S214
if you are using a terminal (such as Hyperterm), you have to send
duration
TRANSCEIVER MODE
(return back in transceiver mode): send the serial
+
+++ (consecutive)
issues on the serial link a +++ sequence. The
ATO <cr>
+
+
Idle line for S214
duration
A
RF54
User Guide
COMMAND
MODE
p. 13
TOP