B41691A7228Q007 EPCOS Inc, B41691A7228Q007 Datasheet - Page 11

Aluminum Electrolytic Capacitors - Leaded 2200UF 40V AL-ELKO AXIAL LEADED

B41691A7228Q007

Manufacturer Part Number
B41691A7228Q007
Description
Aluminum Electrolytic Capacitors - Leaded 2200UF 40V AL-ELKO AXIAL LEADED
Manufacturer
EPCOS Inc
Series
B41691r
Datasheet

Specifications of B41691A7228Q007

Capacitance
2200 uF
Tolerance
- 10 %, 30 %
Voltage Rating
40 Volts
Esr
39 mOhms
Operating Temperature Range
- 55 C to + 150 C
Termination Style
Axial
Dimensions
21 mm Dia. x 39 mm L
Product
General Purpose Electrolytic Capacitors
Load Life
2000 Hrs
Ripple Current
16.1 Amps
Lead Free Status / Rohs Status
No
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling Al electrolytic capacitors:
Please read Cautions and warnings and
Important notes at the end of this document.
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
Page 11 of 16
Long useful life
B41691, B41791
up to 150 C

Related parts for B41691A7228Q007