J List of Parameters
Function Selection Parameters
Note: 1. Do not change the factory settings of any “Reserved” parameters.
Pn000
Pn001
PRM.
No.
2. When changing the Pn000, Pn001, or Pn002 parameter, always turn the main and control circuit power supplies OFF and then ON to validate the
settings.
Function
Selection Basic
Switches
Function
Selection
Application
Switches 1
Parameter name
0
1
2
3
0
1
2
3
Digit
Reverse Rotation
Mode
Mode
Control Mode
Selection
Unit No. Setting
Reserved
Servo OFF or Alarm
Stop Mode
Stop Mode
Run Prohibit Input
Stop Mode
Stop Mode
Main Circuit Power
Supply AC/DC Input
Supply AC/DC Input
Selection
Warning Code Output
Selection
Selection
Function name
(This table continues on the next page.)
Setting
0
1
0
1
2
3
4
5
6
7
8
9
A
B
0 to F
0
1
2
0
1
2
0
1
0
1
Defines forward rotation as counter-
clockwise (CCW) rotation.
Defines forward rotation as clockwise
(CW) rotation.
Speed control (analog command)
Position control (pulse-train command)
Torque control (analog command)
Internally set speed control
Internally set speed control ↔ Speed
control (analog command)
Internally set speed control ↔ Position
control (pulse-train command)
Internally set speed control ↔ Torque
control (analog command)
Position control (pulse-train command)
↔ Speed control (analog command)
Position control (pulse-train command)
↔ Torque control (analog command)
Torque control (analog command) ↔
Speed control (analog command)
Speed control with position lock
function (analog command)
Position control with pulse prohibit
function (pulse-train command)
Sets the unit No. of the device
communicating with Servo Drive.
Uses the dynamic brake to stop the
Servo Motor.
Uses the dynamic brake to stop the
Servo Motor, and releases the dynamic
brake after the Servo Motor stops.
Coasts the Servo Motor to a stop.
Stops the Servo Motor according to the
Pn001.0 setting.
Decelerates the Servo Motor to a stop
at the torque specified in Pn406 and
then locks the Servo Motor.
Decelerates the Servo Motor to a stop
at the torque specified in Pn406 and
then turns OFF the Servo Motor.
Supplies AC power from L1, L2, and
(L3) terminals.
Supplies DC power from (+) 1 and (–)
terminals.
Outputs only alarm codes from AL01,
AL02, and AL03.
Outputs both alarm codes and warning
codes from AL01, AL02, and AL03.
Explanation
0010
1002
Factory
setting
PARAMETERS
---
---
Unit
---
---
Setting
range
45