B7A-R6A18 Omron, B7A-R6A18 Datasheet
B7A-R6A18
Specifications of B7A-R6A18
B7A-R6A18 Summary of contents
Page 1
... High speed 3 ms NPN open collector Normal speed 19 mA/point High speed 3 ms B7A 3/8 èò Error Processing 1: HOLD 3: LOAD OFF 5. I/O Delay (Typical Error processing Part number ------ B7A-T6E3 ------ B7A-T6E8 HOLD B7A-R6A13 LOAD OFF B7A-R6A33 HOLD B7A-R6A18 LOAD OFF B7A-R6A38 ...
Page 2
... B7A-R3A33 B7A-R3A18 B7A-R3A38 C200H High-Density I/O Modules B7A Link Master C200H-ID215 Adapter (16 points) Input Module Two Output Modules B7A-R6A13 B7A-R6A33 B7A-R6A18 B7A-R6A38 2 I/O configuration I/O delay (typical) NPN compatible Normal speed 19.2 ms High speed 3 ms NPN open collector Normal speed 19 mA/point 50 ...
Page 3
... B7A 3/8 C200H High-Density I/O Modules (Group 2) B7A Link Master Adapter (32 points) C200H-ID216 Output Module Input Module B7A-R3A13 B7A-R3A33 B7A-R3A18 B7A-R3A38 B7A Link Master Adapter (32 points) C200H-ID217 Two Output Modules Input Module B7A-R3A13 B7A-R3A33 B7A-R3A18 B7A-R3A38 B7A Link Master Adapter (32 points) ...
Page 4
... B7A 3/8 C500 High-Density I/O Modules The 3G2A5-OD215 cannot be connected due to the difference in terminal arrangement. B7A Link Master Adapter (16 points) Two Output Modules B7A-R6A13 B7A-R6A33 B7A-R6A18 B7A-R6A38 3G2A5-ID218CN Input Module B7A Link Master Adapt- er (32 points) Two Output Modules 3G2A5-ID114 3G2A5-ID219 ...
Page 5
... B7A 3/8 C500 Mixed I/O Module B7A LInk Master Adapter (16 points) Input Module B7A-T6E3 B7A-T6E8 3G2A5-MD211CN Mixed I/O Module Output Unit B7A-R6A13 B7A-R6A33 B7A-R6A18 B7A-R6A38 B7A/B7AS Input Module (16 points) Limit switch, proximity sensor, or photoelectric sensor B7A/B7AS Out- put Module (16 points) Indicator ...
Page 6
... If twisted pair cable is used, however, the transmission distance will maximum regardless of whether or not independent power supplies for the Input and the Output Link Terminals are used. 4. The minimum input time is required for the B7A to read an input signal. 5. Set the timer of the PLC to 0.02 s minimum if a normal--speed model is connected to the PLC. ...
Page 7
... B7A 3/8 Output Models Item B7A-R6A13/-R6A18/-R6A33/-R6A38 Output configuration NPN open collector Current consumption 50 mA max. with all input terminals ON (See Note) Rated load voltage VDC Output residual voltage 0.8 V max. Output current Sink current max./point Error output ...
Page 8
... RAV 1.25 to 3.5 (vinyl--insulated round 2 1.25 mm (AWG#16) ERR ERR1 OUT31 Set the 32nd output to OUT31. B7A 3/8 Function G Lit when power is supplied and the Terminal is operating. N Not lit when power is not supplied. N Not lit when power is supplied and the Terminal is operating without error ...
Page 9
... SIG ERR + SIG -- -- + DC power GND supply ( B7A 3/8 Note: A twisted pair or VCTF cable with a 2 thickness of 0.75 mm min. must be used for signal transmission. Note: In this example, a twisted pair or VCTF transmission cable with a 2 thickness of 0.75 mm min. is used, through which a current of 1.8 A max. can be transmitted. ...
Page 10
... SIG1 SIG2 -- Transmission distance 100 m max power supply ( B7A 3/8 2 cable with a thickness of 0.75 mm min. is used, through which a current of 1.8 A max. can be transmitted recom-- mended that the shield be grounded Note: A VCTF cable with a 2 thickness of 0.75 mm min. must be used for signal transmission. ...
Page 11
... B7A 3/8 I/O Delay: High Speed Connection of Independent Power Supplies Input SIG SIG + -- -- power supply ( Connection of Single Power Supply to Two Input or Output Terminals Input SIG SIG + -- -- B7A LINK MASTER ADAPTERS WITH HIGH-DENSITY PLC I/O MODULES Input Model I/O I/O Input points ...
Page 12
... B7A 3/8 Output Model I/O I/O Error points delay processing B7A-R6A13 16 19.2 9 HOLD ms B7A-R6A33 LOAD OFF B7A-R6A18 HOLD B7A-R6A38 LOAD OFF B7A-R3A13 32 19.2 9 HOLD ms B7A-R3A33 LOAD OFF B7A-R3A18 HOLD B7A-R3A38 LOAD OFF Connection with PLC Plug in the B7A Output Adapter to the ...
Page 13
... B7A 3/8 Dimensions Unit: mm (inch) 16-point Link Master Adapters 32-point Link Master Adapters 56 (2.20) 53 (2.09) 12.6 (0.50) 16 (0.63) 5.4 56 (2.20) 73.3 (2.89) 12.6 (0.50) 16 (0.63) 5.4 B7A 3/8 Two, M2.6 Four, M3.5 Two, M2.6 Seven, M3.5 13 ...
Page 14
... B7A 3/8 Installation 3 INTERNAL CIRCUITS AND TERMINAL ARRANGEMENT 16-point Link Master Adapters B7A-T6E3/-T6E8 (Input, Active Low) Transmission line SIG + VDC Terminal board Connector B7A-R6A13/-R6A18/-R6A33/-R6A38 (Output, NPN Open Collector) Transmission line Fuse SIG (See Note VDC _ ERR Terminal board Terminal No ...
Page 15
... Note: Do not short-circuit the SIG terminal with a positive or negative power supply terminal, or the internal elements of B7A will be damaged and no transmission will occur. + IN00 to IN31 Connector _ Connector Terminal Terminal No. Terminal IN12 29 -- IN13 30 + IN14 31 IN24 IN15 32 IN25 -- 33 IN26 + 34 IN27 IN16 35 IN28 IN17 36 IN29 IN18 37 IN30 IN19 38 IN31 IN20 39 -- IN21 40 + IN22 IN23 B7A 3/8 Terminal board 15 ...
Page 16
... B7A 3/8 B7A-R3A13/-R3A33/-R3A18/-R3A38 (Output, NPN Open Collector) Transmission line SIG1 Fuse (See note 3) SIG2 + VDC ERR1 ERR2 Terminal board SIG1: OUT00 to OUT15 SIG2: OUT16 to OUT31 Terminal No. Terminal Terminal No. 1 OUT00 15 2 OUT01 16 3 OUT02 17 4 OUT03 18 5 OUT04 ...