B7A-T6E3 Omron, B7A-T6E3 Datasheet

no-image

B7A-T6E3

Manufacturer Part Number
B7A-T6E3
Description
TERM BLOCK PLC 16POS NPN INPUT
Manufacturer
Omron
Datasheet

Specifications of B7A-T6E3

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
B7AT6E3
Connect High-Density I/O PLC
Modules to 16-Point B7A Modules
1
1
1
1
1
Ordering Information
3 MODEL NUMBER LEGEND
Input Models
3 LINK MASTER ADAPTERS FOR HIGH-DENSITY I/O PLC MODULES
16- -point Adapters
1. Input/OutputClassification
T: Input
2. Number of I/O
6: 16
3: 32
B7A - - T
Link Master Adapter
Adapter for Omron high-density I/O PLC
modules connects 32 points, eliminates
need for a second Link Interface module
Transmits 16 input signals over 2 wires;
32 input signals over just 3 wires
Normal I/O delay (19.2 ms typical) or
short I/O delay (3 ms typical) models
16- and 32-point connectors available
Output models offer Hold or Load Off
options for handling transmission errors
Appearance
1 2 3 4
E
I/O classification
Input
Output
9
3. In put Configuration
E: NPN compatible
4. I/O Delay (Typical)
3: 19.2 ms
8: 3 ms
NPN compatible
NPN open collector
50
50 mA/point
I/O configuration
A/
i t
Normal speed 19.2 ms
High speed 3 ms
Normal speed 19.2 ms
High speed 3 ms
Output Models
1. Input/Output Classification
R: Output
2. Number of I/O
6: 16
3: 32
3. Output Configuration/
A: NPN open collector/
I/O delay (typical)
B7A - - R
Capacity
50 mA/point
1 2 3 4
A
------
------
HOLD
LOAD OFF
HOLD
LOAD OFF
Error processing
5
B7A-P P P P P P P P P P P P 3/8
4. Error Processing
1: HOLD
3: LOAD OFF
5. I/O Delay (Typical)
3: 19.2 ms
8: 3 ms
èò
B7A-T6E3
B7A-T6E8
B7A-R6A13
B7A-R6A33
B7A-R6A18
B7A-R6A38
Part number

B7A-T6E3 Summary of contents

Page 1

... High speed 3 ms NPN open collector Normal speed 19 mA/point High speed 3 ms B7A 3/8 èò Error Processing 1: HOLD 3: LOAD OFF 5. I/O Delay (Typical Error processing Part number ------ B7A-T6E3 ------ B7A-T6E8 HOLD B7A-R6A13 LOAD OFF B7A-R6A33 HOLD B7A-R6A18 LOAD OFF B7A-R6A38 ...

Page 2

... Input Module B7A-T3E3 B7A-T3E8 B7A/B7AS In- put Module (16 points) Limit switch, proximity sensor, or photoelectric sensor B7A Link Master Adap- ter (16 points) Two Input Modules B7A-T6E3 B7---T6E8 B7A/B7AS In- put Module (16 points) Limit switch, proximity sensor, or photoelectric sensor B7A 3/8 Error processing Part number ------ B7A-T3E3 ...

Page 3

... B7A 3/8 C200H High-Density I/O Modules (Group 2) B7A Link Master Adapter (32 points) C200H-ID216 Output Module Input Module B7A-R3A13 B7A-R3A33 B7A-R3A18 B7A-R3A38 B7A Link Master Adapter (32 points) C200H-ID217 Two Output Modules Input Module B7A-R3A13 B7A-R3A33 B7A-R3A18 B7A-R3A38 B7A Link Master Adapter (32 points) ...

Page 4

... Two Output Modules 3G2A5-ID114 3G2A5-ID219 B7A-R3A13 Input Module B7A-R3A33 B7A-R3A18 B7A-R3A38 4 B7A LInk Master Adapter (16 points) Two Input Module B7A-T6E3 B7A-T6E8 B7A/B7AS In- put Module (16 points) Limit switch, proximity sensor, or photoelectric sensor B7A Link Master Adapter (32 points) Two Input Modules B7A-T3E3 ...

Page 5

... B7A 3/8 C500 Mixed I/O Module B7A LInk Master Adapter (16 points) Input Module B7A-T6E3 B7A-T6E8 3G2A5-MD211CN Mixed I/O Module Output Unit B7A-R6A13 B7A-R6A33 B7A-R6A18 B7A-R6A38 B7A/B7AS Input Module (16 points) Limit switch, proximity sensor, or photoelectric sensor B7A/B7AS Out- put Module (16 points) Indicator ...

Page 6

... Normal speed 100 m max. (See Note 3) Typical max. 2 (approx. 30G) -- (-- 149 F) with no icing 16-point B7A-T6E3/-T6E8 100 mA max. with all input terminals ON OFF voltage: 5.5 V min. ON discrimination resistance: OFF discrimination resistance B7A 3/8 High speed 2 minimum must be used for signal trans-- ...

Page 7

... B7A 3/8 Output Models Item B7A-R6A13/-R6A18/-R6A33/-R6A38 Output configuration NPN open collector Current consumption 50 mA max. with all input terminals ON (See Note) Rated load voltage VDC Output residual voltage 0.8 V max. Output current Sink current max./point Error output ...

Page 8

... RAV 1.25 to 3.5 (vinyl--insulated round 2 1.25 mm (AWG#16) ERR ERR1 OUT31 Set the 32nd output to OUT31. B7A 3/8 Function G Lit when power is supplied and the Terminal is operating. N Not lit when power is not supplied. N Not lit when power is supplied and the Terminal is operating without error ...

Page 9

... SIG ERR + SIG -- -- + DC power GND supply ( B7A 3/8 Note: A twisted pair or VCTF cable with a 2 thickness of 0.75 mm min. must be used for signal transmission. Note: In this example, a twisted pair or VCTF transmission cable with a 2 thickness of 0.75 mm min. is used, through which a current of 1.8 A max. can be transmitted. ...

Page 10

... SIG1 SIG2 -- Transmission distance 100 m max power supply ( B7A 3/8 2 cable with a thickness of 0.75 mm min. is used, through which a current of 1.8 A max. can be transmitted recom-- mended that the shield be grounded Note: A VCTF cable with a 2 thickness of 0.75 mm min. must be used for signal transmission. ...

Page 11

... Connection of Single Power Supply to Two Input or Output Terminals Input SIG SIG + -- -- B7A LINK MASTER ADAPTERS WITH HIGH-DENSITY PLC I/O MODULES Input Model I/O I/O Input points delay configuration B7A-T6E3 16 19.2 NPN ms compatible B7A-T6E8 3 ms B7A-T3E3 32 19.2 ms B7A-T3E8 3 ms Output SIG SIG ERRERR ...

Page 12

... Yes Yes ------ ------ ------ Yes Yes ------ ------ ------ Yes Yes ------ ------ ------ Yes Yes Plug in the B7A Input Adapter to the receptacle on the PLC Output Module PLC Output Module OUT IN B7A 3/8 C500 CQM1 ID218CN MD211CN ID114 ID219 ID213 Yes Yes ------ ------ ------ Yes Yes ------ ------ ------ Yes Yes ------ ------ ------ ...

Page 13

... B7A 3/8 Dimensions Unit: mm (inch) 16-point Link Master Adapters 32-point Link Master Adapters 56 (2.20) 53 (2.09) 12.6 (0.50) 16 (0.63) 5.4 56 (2.20) 73.3 (2.89) 12.6 (0.50) 16 (0.63) 5.4 B7A 3/8 Two, M2.6 Four, M3.5 Two, M2.6 Seven, M3.5 13 ...

Page 14

... B7A 3/8 Installation 3 INTERNAL CIRCUITS AND TERMINAL ARRANGEMENT 16-point Link Master Adapters B7A-T6E3/-T6E8 (Input, Active Low) Transmission line SIG + VDC Terminal board Connector B7A-R6A13/-R6A18/-R6A33/-R6A38 (Output, NPN Open Collector) Transmission line Fuse SIG (See Note VDC _ ERR Terminal board Terminal No ...

Page 15

... Note: Do not short-circuit the SIG terminal with a positive or negative power supply terminal, or the internal elements of B7A will be damaged and no transmission will occur. + IN00 to IN31 Connector _ Connector Terminal Terminal No. Terminal IN12 29 -- IN13 30 + IN14 31 IN24 IN15 32 IN25 -- 33 IN26 + 34 IN27 IN16 35 IN28 IN17 36 IN29 IN18 37 IN30 IN19 38 IN31 IN20 39 -- IN21 40 + IN22 IN23 B7A 3/8 Terminal board 15 ...

Page 16

... B7A 3/8 B7A-R3A13/-R3A33/-R3A18/-R3A38 (Output, NPN Open Collector) Transmission line SIG1 Fuse (See note 3) SIG2 + VDC ERR1 ERR2 Terminal board SIG1: OUT00 to OUT15 SIG2: OUT16 to OUT31 Terminal No. Terminal Terminal No. 1 OUT00 15 2 OUT01 16 3 OUT02 17 4 OUT03 18 5 OUT04 ...