Z0220112VSGR4078 Zilog, Z0220112VSGR4078 Datasheet - Page 66

IC MODEM 2400BPS DSP AFE 44-PLCC

Z0220112VSGR4078

Manufacturer Part Number
Z0220112VSGR4078
Description
IC MODEM 2400BPS DSP AFE 44-PLCC
Manufacturer
Zilog

Specifications of Z0220112VSGR4078

Data Format
V.21, V.22, V.23, Bell 103, Bell 212A
Baud Rates
2.4k
Interface
Parallel
Voltage - Supply
4.5 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
44-LCC (J-Lead)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z0220112VSGR4078
Manufacturer:
Zilog
Quantity:
10 000
Making a V.22bis Connection
PS000904-0107
Originating Modem
Answering Modem
9. Set TRNCTRL, bit
10. Set TRNCTRL, bits
11. Set TRNCTRL, bits
12. If in step 6., SB1 is received instead of an S1 signal, set TRNCTRL, bits
In the following example, all timing is performed by the host.
1. Take the telephone line OFF-HOOK and dial.
2. Program the discrete tone detectors and the biquad tone detectors for answer
3. Upon receiving the 2100 Hz answer tone, set CONFIG to
4. When the data pump establishes a V.22bis connection, and is ready to
1. Upon a ring signal or command from the terminal, take the phone off-hook and
2. If required, use the tone generators to transmit a 2100 Hz tone for 2.6–4
3. Set CONFIG register, bits 0–6 (MODE) to
150 msec.
msec.
being transmitted and received at 2400 bps.
(TXCTRL) to 3 (Transmit SB1) for 765 msec. From that point, set TRNCTRL,
bits
received at 1200 bps.
tones (2100 Hz) and call-progress tones (200–600 Hz). Look for the answer
tone and call-progress tones (busy tones, ring back, etc.)
originate). After setting Config, the host should be prepared to receive data
from the remote modem. The data pump holds the received data to marks
(that is, receives nothing) until the modem is able to receive data from the
remote modem.
transmit data to the remote modem, it sets Reg5, bit
now be transmitted or received between the modems.
transmit silence for 1.8–2.5 seconds.
seconds. This tone is the V.25 answer tone.
75 msec.
0
2
(TXCTRL) to 5 (1200 bps DATA mode). Data is now transmitted and
3
0
0
(V22BIS) to 1 (force 16-way receive decisions). Wait for
2
2
(TXCTRL) to
(TXCTRL) to 6 (2400 bps data mode). Data is now
V.22BIS Data Pump with Integrated AFE
4
(transmit SB1 at 2400 bps). Wait for 200
0
(STANDBY) and transmit silence for
1
(CDET) to 1. Data may
4008h
(V.22bis
0
2
62

Related parts for Z0220112VSGR4078