R88A-CAWB015S Omron, R88A-CAWB015S Datasheet - Page 31

no-image

R88A-CAWB015S

Manufacturer Part Number
R88A-CAWB015S
Description
POWER CABLE 15M
Manufacturer
Omron
Datasheet

Specifications of R88A-CAWB015S

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88ACAWB015S
3G3MV
General Specifications
Inverter PLC Specifications
For complete specifications and additional models:
Protective functions
Motor overload protection
Instantaneous overcurrent
Overload
Overvoltage
Undervoltage
Momentary power loss
Cooling method
Cooling fin overheat
Cooling fan fault
Stall prevention
Ground fault
Power charge indication
Environmental conditions
Enclosure rating
Location
Ambient temperature
Storage temperature
Humidity
Elevation
Wiring distance
Vibration
Other functions
Multi-function inputs
Multi-function outputs
Standard functions
Model
Type
I/O points
Clock/calendar
Encoder interface
Connectivity
Memory backup
Dimensions
Software
Inverters
3G3MV-P10CDT3-E
Full feature PLC installs on face of 3G3MV inverters with 1/4 to 10 HP rating
6 input points (bi-directional input at 5 kHz; unidirectional input at 20 kHz)
4 output points (1 relay, 3 NPN transistor);
I/O can be set for interrupt inputs (50 µs response) or pulse outputs
Yes
Yes
Direct HMI connection
Peripheral port
Serial ports: RS-232C, RS-422/485
Flash memory and battery
128 H x 68 W x 38.1 D mm
CX-Programmer included in CX-One
UL-recognized electronic thermal overload relay
Motor coasts to a stop at approximately 250% inverter rated current
Motor coasts to a stop after one minute at 150% rated output current
Motor coasts to a stop if DC bus voltage exceeds 410 V Motor coasts to a stop if DC bus voltage exceeds 820 V
Stops when DC bus voltage is approximately 200 V or
less (approx. 160 V or less for single-phase series)
Stops if power loss is 15 ms or more. By setting inverter, operation can be continued if power is restored within
approximately 0.5 s
Cooling fan is provided for the following models:
200 V, 0.75 kW or larger inverters (3-phase)
200 V, 1.5 kW or larger inverters (single-phase)
Others models are self-cooling
Protected by electronic circuit
Protected by electronic circuit (fan lock detection)
Individual levels during acceleration/running, enable/disable provided during coast to a stop
Protected by electronic circuit (overcurrent level)
ON until the DC bus voltage becomes 50 V or less. RUN lamp stays ON or digital operator LED stays ON.
Enclosed wall mounted NEMA 1
Indoor (free from corrosive gases and dust)
Enclosed wall mounted NEMA 1: 14 to 105° F (-10 to +40°C), not frozen
-4 to 140°F (-20 to 60°C)
95% RH or less (Non-condensing)
1,000 m (3,281 feet) or below
328 ft (100 m) or less between inverter and motor
9.8 m/s
Seven of the following input signals are selectable: Forward/reverse run (3-wire sequence), fault reset, external
fault (NO/NC contact input), multi-step speed operation, Jog command, accel/decel time select, external base
block (NO/NC contact input), speed search command, UP/DOWN command, accel/decel hold command,
LOCAL/REMOTE selection, communication/control circuit terminal selection, emergency stop fault, emergency
stop alarm, self test, PID control cancel, PID integral reset/hold
Following output signals are selectable (1 NO/NC contact output, 2 photo-coupler outputs): Fault, running, zero
speed, at frequency, frequency detection (output frequency = or = set value), during overtorque detection,
during undervoltage detection, minor error, during baseblock, operation mode, inverter run ready, during fault
retry, during UV, during speed search, data output through communication, PID feedback loss detection
Voltage vector control, full-range automatic torque boost, slip compensation, DC injection braking current/time
at start/stop frequency reference bias/gain, MEMOBUS communications (RS-485/422, max. 19.2 K bps), PID
control, energy-saving control, parameter copy, frequency reference with built-in potentiometer
2
(Continued)
(1G) less than 20 Hz, up to 2 m/s
U.S. www.omron.com/oei Canada www.omron.ca
2
(0.2G) at 20 to 50 Hz
3G3MV-P10CDT-E
No
Yes
Direct HMI connection
Peripheral port
RS-232C serial port
Flash memory and capacitor
Stops when DC bus voltage is approximately 400 V or
less
I-23