The procedure for making up the cable is described below.
Also refer to this procedure for making a connecting cable for use with RS-422A/485 connections.
Cable Preparation
The preparation of the cable differs according to whether or not the shielding wire is to be connected to the FG.
Cable with Shielding Wire Connected to FG
1,2,3....
1. Cut the cable to the required length.
2. Remove the external vinyl insulation from the cable with a razor blade. Take care not to damage the shielding
3. Cut back the shielding wire with scissors.
4. Use wire strippers to strip the insulation from each wire.
5. Fold back the shielding wire.
6. Wrap aluminum foil tape around the folded-back shielding wire.
Cable with Shielding Wire Not Connected to FG
1,2,3...
1. Cut the cable to the required length.
2. Remove the external vinyl insulation from the cable with a razor blade. Take care not to damage the shielding
3. Cut back the shielding wire with scissors.
4. Use wire strippers to strip the insulation from each wire.
5. Wrap vinyl tape over the cut off end of the shielding wire.
underneath.
underneath.
(1)
(2)
(3)
(4)
(5)
(6)
(0.19)
Units: mm (inch)
5
Making the Cable
40 (1.57) (RS-232C)
25 (0.98) (RS-422A)
Appendix E
(0.39)
10
Aluminum foil tape
267