R88A-CAWC005B Omron, R88A-CAWC005B Datasheet - Page 51

no-image

R88A-CAWC005B

Manufacturer Part Number
R88A-CAWC005B
Description
POWER CABLE (WITH BRAKE) 5M
Manufacturer
Omron
Datasheet

Specifications of R88A-CAWC005B

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88ACAWC005B
ALARM LIST
J Alarm Displays
Note:
44
Display
Alarm codes are output to pin 37 (AL01), pin 38 (AL02), and pin 39 (AL03) of the CN1 connector on the Servo Drive.
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
OFF
AL01
Alarm code
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
AL02
OFF
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
AL03
Parameter destruction, Servo Drive EEP-ROM data error
Main circuit detector error
Parameter setting error
Motor mismatch, Servo motor and Servo Drive capacity mismatch
Overcurrent or heat sink overheating (1.5 kW min.)
Regeneration error (broken resistor wiring, transistor short-circuit )
Regeneration overload
Overvoltage
Undervoltage
Overspeed
Overload (maximum momentary load)
Overload (maximum continuous load)
Dynamic brake overload
Inrush resistance overload
Radiation shield overheating (Displayed for 30 W to 1.0 kW models only)
Backup error
Checksum error
Parity error
Absolute error
Overspeed error
Encoder overheating
Speed command input read error
Torque command input read error
System error
Overrun detection
Excessive rotation data error
Encoder communications error
Encoder parameter error
Encoder data error
Multiple rotation limit mismatch
Error counter count-up
Phase-failure detected
Alarm details