NT31C-CFL01 Omron, NT31C-CFL01 Datasheet - Page 307

no-image

NT31C-CFL01

Manufacturer Part Number
NT31C-CFL01
Description
NT31/31C REPLACEMENT BACKLIGHT
Manufacturer
Omron
Datasheet

Specifications of NT31C-CFL01

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
NT31CCFL01
3-4
3-4-1 Opening/Closing/Moving a Window
298
Display and Control of Windows
Display and Control of Windows
Reference:
Reference:
S Window screen is called window/keyboard screen at the Support Tool.
S Window has the following two types.
S If 1 (disable) is set for the window opening PT status control bit, it is not pos-
S Touch switch operation will be disabled when the touch switch interlock func-
S If the window for which open is specified is not a window screen, the window
S When creating a screen with the Support Tool, it is possible to designate a win-
A window means a partial screen which can be displayed on the presently dis-
played screen (base screen).
A window can be created by registering a screen under a screen number from 1
to 3999 as a window screen.
This section describes the following types of operation which can be performed
for a window.
• Opening/closing/moving a window
• Checking the display status of a window
• Disabling/enabling the opening of a window
The PT provides the following methods to open/close/move a window.
• Pressing a touch switch that has the input key-window/keyboard function.
• Pressing a touch switch that has the cursor moving key function. (window
• Pressing a touch switch that has the window moving key function. (window
• Controlling the window by the operation of the window control area from the
• Setting Load Local 1 (Keyboard), Load Local 2 screen attribute for a standard
sible to open a window by operation at the PT. (Closing of a window is al-
lowed.)
tion is being used and the host’s interlock bit that controls the touch switch’s
operation is OFF. (See Disabling Touch Switches with Interlock Bits on page
357 for details.)
open command is disregarded.
dow which is opened at the same time the screen is displayed (set with the
Load Window/Keyboard Screen attribute of Screen Property).
(Opening/closing are possible)
opening only)
moving only)
host (Window opening/closing/moving are possible)
screen and perform screen switch. (window opening only)
Global window :
Local window :
Section
3-4