STMPE24M31QTR STMicroelectronics, STMPE24M31QTR Datasheet - Page 61

IC SENSOR S-TOUCH 24CH 40QFN

STMPE24M31QTR

Manufacturer Part Number
STMPE24M31QTR
Description
IC SENSOR S-TOUCH 24CH 40QFN
Manufacturer
STMicroelectronics
Series
S-Touch™r
Type
Capacitiver
Datasheets

Specifications of STMPE24M31QTR

Number Of Inputs/keys
24 Key
Data Interface
I²C
Data Rate/sampling Rate (sps, Bps)
100k, 400k
Voltage Reference
External
Voltage - Supply
1.65 V ~ 1.95 V
Current - Supply
900µA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-VQFN
Output Type
Logic
Interface
I²C
Input Type
Logic
Supply Voltage
1.8 V
Number Of Channels
24
Dimensions
5 mm L x 5 mm W x 0.85 mm H
Temperature Range
- 40 C to + 85 C
Termination Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-10380-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STMPE24M31QTR
Manufacturer:
STM
Quantity:
8 061
Part Number:
STMPE24M31QTR
Manufacturer:
ST
0
STMPE16M31, STMPE24M31
RATIO_ENG_SET
Address:
Type:
Reset:
Description:
RESERVED
RW
7
0
DATAMODE
[7] RESERVED
[6] DATAMODE
[5] RE2FilterEn
[4] RE1FilterEn
[3] CFG2
[2] CFG1
[1] EN2
[0] EN1
RW
6
0
Setting of data presentation
‘1’ to display 1 byte position data in the first byte of RE1_POS and RE2_POS continuously. The
old data will be overwritten. In this mode, when touch is detected in the slider, interrupt is issued
and host can read the data in its own rate. Only position data is available (8 bits), movement
and time-stamp data are not available.
‘0’ to enable data-buffering. Position, movement and time-stamp are available.
Ratio engine 2 noise filter
‘1’ to enable the filter
‘0’ to disable the filter
Ratio engine 1 noise filter
‘1’ to enable the filter
‘0’ to disable the filter
Ratio engine 2 setting
‘1’ for rotator/wheel configuration
‘0’ for linear/slider configuration
Ratio engine 1 setting
‘1’ for rotator/wheel configuration
‘0’ for linear/slider configuration
‘1’ to enable ratio engine 2
‘0’ to enable ratio engine 1
‘1’ to enable ratio engine 2
‘0’ to enable ratio engine 1
0x80
RW
0x00
Operation setup of ratio engine.
RE2FilterEn
RW
5
0
RE1FilterEn
Doc ID 16174 Rev 3
RW
4
0
CFG2
RW
3
0
Ratio engine setup register
CFG2
RW
2
0
Touch sensor controller
EN2
RW
1
0
EN1
RW
0
0
61/85

Related parts for STMPE24M31QTR