Page 1
... Active-High/Low Control Logic o Fault-Indicator Output o Thermal-Overload Protection o Smaller 4mm x 4mm Thin QFN Package (MAX1563) o 3µA Shutdown Current Ordering Information PART TEMP RANGE MAX1562ESA+ -40°C to +85°C MAX1562HESA+ -40°C to +85°C MAX1563ETC+ -40°C to +85°C + Denotes a lead(Pb)-free/RoHS-compliant package Exposed pad. ...
Page 2
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking ABSOLUTE MAXIMUM RATINGS IN, ON, ON, ISET, SEL, OUT to GND .......................-0.3V to +6V FAULT to GND .............................................-0. OUT..................................................................-0.3V to +6V OUT Maximum Continuous Switch Current ...
Page 3
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking ELECTRICAL CHARACTERISTICS (continued +5V 1µ 4.7µ OUT PARAMETER SYM Output Fall Time t FALL Thermal-Shutdown Threshold ON, ON, ...
Page 4
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking ELECTRICAL CHARACTERISTICS (continued +5V 1µ 4.7µ OUT PARAMETER SYM Turn-On Delay t Turn-Off Delay t OFF ON, ON, ...
Page 5
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking (V = +5V 1µ 4.7µ OUT NORMALIZED R vs. TEMPERATURE ON 1.3 1.2 1.1 1.0 0.9 0.8 0.7 -40 - ...
Page 6
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking (V = +5V 1µ 4.7µ OUT SWITCH TURN-ON TIME V ON (MAX1562 (MAX1562H) V OUT 1ms/div STARTUP TIME Ω ...
Page 7
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking PIN MAX1562 NAME MAX1563 MAX1562H (TQFN-EP (ON) FAULT GND 4 7 ISET OUT ...
Page 8
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking following equation 17120 / R LIM ISET Choose R with resistor values between 4.22kΩ to ISET 16kΩ. Resistor values greater than 16kΩ significantly degrade current-limit accuracy. For the ...
Page 9
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking Table 2. Current Limiting and Fault Behavior CONDITION • short is detected at the output, the channel turns off, and the blanking timer begins. FAULT remains high during ...
Page 10
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking ramps down for 800µs. Under fault conditions, the output of the switches turns off rapidly to provide maximum safe- ty for the upstream power source and downstream devices. Internal blocks ...
Page 11
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking Chip Information TRANSISTOR COUNT: 1833 PROCESS: BiCMOS For the latest package outline information and land patterns www.maxim-ic.com/packages. Note that a “+”, “#”, or “-” in the package code ...
Page 12
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking For the latest package outline information and land patterns www.maxim-ic.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may ...
Page 13
Programmable 4A USB Current-Limited Switches with Autoreset and Fault Blanking For the latest package outline information and land patterns www.maxim-ic.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may ...
Page 14
... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. 14 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2010 Maxim Integrated Products ...