VHB75W-Q24-S48 CUI Inc, VHB75W-Q24-S48 Datasheet - Page 7

CONVERTER DC/DC 75W 48V 1.56A

VHB75W-Q24-S48

Manufacturer Part Number
VHB75W-Q24-S48
Description
CONVERTER DC/DC 75W 48V 1.56A
Manufacturer
CUI Inc
Series
V-Infinity VHB75Wr
Type
With Remote On/Off and UVLOr
Datasheet

Specifications of VHB75W-Q24-S48

Voltage - Input (min)
9V
Voltage - Input (max)
36V
Number Of Outputs
1
Power (watts) - Manufacture Series
75W
Power (watts) - Max
75W
1st Output
48 VDC @ 1.56A
2nd Output
-
3rd Output
-
Voltage - Isolation
1.5kV (1500V)
Mounting Type
Through Hole
Package / Case
9-DIP Module, 1/2 Brick
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Operating Temperature
-40°C ~ 100°C
Efficiency
82%
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
102-2245
PART NUMBER: VHB75W
8. OUTPUT OCP AND SHORT-CIRCUIT PROTECTION
Output overload and short circuit conditional will cause the output voltage to decline or shutdown altogether.
is not over 100°C, the output recovers automatically when the short or OCP conditions are removed. In the case of slight overloading,
the output voltage may not shut down, but the converter may build up heat over time, causing over-temperature shutdown.
9. OVER-TEMPERATURE PROTECTION
When the case temperature reaches about 100°C, the converter's built-in protection circuit will shut down the output. When the tem-
perature is reduced enough to a safe operating level, the converter will recover to normal operations automatically.
10. OUTPUT OVP
In case the output voltage exceeds the OVP threshold, the converter shuts down.
11. OUTPUT PARALLEL CONNECTIONS
The converter is not designed for load share on the output. One may be inclined to use this circuit to force current sharing by trim-
ming the output voltages for each converter. However, this circuit may not reliably or accurately divide the load current, as the device
characteristics of the converters or the diodes may not be balanced over a range of operating conditions. We generally do not recom-
mend this circuit to increase power output over a single converter. Instead, we recommend this setup for redundancy only, having
one converter as a backup in case of a failure. Make sure the OR-ing diodes can handle the voltage and full load current.
20050 SW 112
FIGURE 6. OUTPUT
PARALLEL CONNECTIONS
th
Ave. Tualatin, Oregon 97062
phone
phone 503.612.2300 fax
+Vin
-Vin
+Vin
-Vin
DESCRIPTION: half-brick dc-dc converter
+Vo
+Vo
-Vo
-Vo
fax 503.612.2383
www.v-infinity.com
If the case temperature
page
date
04/2011
7 of 10