SFS4-SFD Panasonic Electric Works, SFS4-SFD Datasheet - Page 5

no-image

SFS4-SFD

Manufacturer Part Number
SFS4-SFD
Description
SOCKET RELAY DIN MNT FOR 4P
Manufacturer
Panasonic Electric Works
Series
SFSr
Type
Socketr
Datasheet

Specifications of SFS4-SFD

Number Of Positions
10
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
SFS Relays
For Use With
255-3095 - RELAY SAFETY 4PST 6A 24VDC PCB255-3094 - RELAY SAFETY 4PST 6A 12VDC PCB
Other names
255-3099
<When installing>
<When removing>
SFS
NOTES
1. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%. However,
check it with the actual circuit since the
characteristics may be slightly different.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or
malfunction.
3. Cleaning
This relay is not sealed, therefore,
immersion may cause failure. Be careful
that flux does not overflow onto the PC
board or penetrate inside the relay.
4. Soldering
When using automatic soldering, the
following conditions are recommended
1) Preheating: 120 C
Sec (PC board solder surface)
2) Soldering: 260 C 5 C
within 6 Sec
5. Installation
1) Attach directly to the chassis or use a
DIN rail.
(1) When attaching directly to chassis
• Use a M3.5 screw, spring washer, and
• For the mounting pitch, refer to the
(2) When installing on a DIN rail
• Use a 35 mm 1.378 inch wide DIN rail
• Install and remove as shown in the
For Cautions for Use.
hex nut.
dimensions.
(DIN46277).
figures below.
DIN rail
248
Push
500 F 41
F, within 120
Pull
Screwdriver
F,
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
2) Refer to the figure below for applicable
wire-pressed terminals.
(You cannot use round type wire-pressed
terminals.)
6. Other
1) If the relay has been dropped, the
appearance and characteristics should
always be checked before use.
2) The switching lifetime is defined under
the standard test condition specified in
the JIS* C 5442-1996 standard
(temperature 15 to 35 C
humidity 25 to 75%). Check this with the
actual product as it is affected by the coil
driving circuit, load type, activation
frequency, activation phase, ambient
conditions and other factors.
Also, be especially careful with loads
such as those listed below.
(1) When used for AC load-operation and
the operating phase is synchronous.
Rocking and fusing can easily occur due
to contact shifting.
(2) During high frequency on/off
operation with certain loads, arcing may
occur at the contacts. This can cause
fusion to Oxygen and Nitrogen gas in the
air creating Nitric Acid (HNO
cause corrosion to the contacts.
Please see the following countermeasure
examples:
3) For secure operations, nominal coil
voltage should be applied. In addition,
please note that pick-up and drop-out
voltage will vary according to the ambient
temperature and operating conditions.
4) Heat, smoke, and/or fire may occur if
the relay is used outside the allowable
ranges for the coil ratings, contact
ratings, operating cycle lifetime, and
other specifications. Therefore, do not
use the relay if these ratings are
exceeded. Also, make sure that the relay
is wired correctly.
5) Incorrect wiring may cause false
operation or generate heat or flames.
6) Check the ambient conditions when
storing or transporting the relays and
devices containing the relays. Freezing or
condensation may occur in the relay
causing damage. Avoid exposing the
relays to heavy loads, or strong shock
and vibration.
.248 inch max. .118 inch min.
6.3 mm max.
1. Incorporate an arc-extinguishing
2. Lower the operating frequency
3. Lower the ambient humidity
circuit.
3 mm min.
59 to 95
3
) which can
F,
7. Usage, transport and storage
conditions
1) Ambient temperature, humidity, and
atmospheric pressure during usage,
transport, and storage of the relay:
(1) Temperature:
–40 to +85 C
(When the temperature is 70 to 80 C,
reduce the 6 A max. switching current by
0.1 A/ C.)
(2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
(3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for
usage, transport, and storage
2) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the
temperatures is lower than 0 C
causes problems such as sticking of
movable parts or operational time lags.
4) Low temperature and low humidity
At low temperature, low humidity
environments, the plastic becomes brittle.
Please note corrections.
8. Please connect DC coil types with
LED and built-in diode correctly by
verifying the coil polarity (“+” and “–
”). Connecting with reverse polarity
will cause the LED not to light and
damage the built-in diode due to its
specification.
(Avoid freezing
when used at
temperatures
lower than
0 C
–40
–40
32
F)
Tolerance range
–40 to +185 F
85
5
+32
0
(Avoid
condensation
when used at
temperatures
higher than
0 C
Humidity, %RH
Temperature, C
32
F)
F
32
+185
85
F. This

Related parts for SFS4-SFD