PY11-0 Omron, PY11-0 Datasheet - Page 3

no-image

PY11-0

Manufacturer Part Number
PY11-0
Description
SOCKET PCB FOR MY3
Manufacturer
Omron
Series
MYr
Type
Socketr
Datasheet

Specifications of PY11-0

Number Of Positions
11
Mounting Type
Through Hole
Termination Style
PC Pin
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
MY3 Relays
Other names
PY110
■ Characteristics
Note: The values given above are initial values.
Endurance Characteristics
Note: See following tables for real load life expectancies.
■ Endurance Under Real Loads
MY2
MY4
64
Contact resistance
Operate time
Release time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature*
Ambient humidity
Weight
Normal
With bifurcated contacts
100 VAC
100 VAC
24 VDC
Rated voltage
Rated voltage
General-purpose Relay
AC motor
AC solenoid
AC solenoid
DC magnetic
switch
AC magnetic
switch
DC solenoid
Contact form
Item
Load type
Load type
50 W, 100 VAC single-phase with 2.8-A in-
rush current, 0.4-A carry current
50 W, 100 VAC single-phase with 1.6-A in-
rush current, 1-A carry current
24 W with 1-A carry current
50 VA with 2-A inrush current, 0.7-A carry
current
25 W with L/R = 40 ms , 0.2-A carry current
35 VA with 1.5-A inrush current, 0.35-A
carry current
40 W with L/R = 10 ms, 1.6-A carry current ON for 0.5 s, OFF for 1.5 s
30 W with L/R = 10 ms with 0.34-A carry
current
MY
50 m max.
20 ms max.
20 ms max.
Mechanical:
Electrical:
1,000 M
2,000 VAC, 50/60 Hz for 1 min (1,000 VAC between contacts of same polarity)
Destruction:
Malfunction:
Destruction:
Malfunction:
See following table.
Operating: (standard):
Built-in LED indicator; built-in diode:
Operating:
Approx. 35 g
Conditions
Conditions
AC:
DC:
4-pole: 20,000,000 operations min.
min. (at 500 VDC)
50,000,000 operations min.
100,000,000 operations min.
(at 18,000 operations/hr)
5% to 85%
10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
18,000 operations/hr
1,800 operations/hr (under rated load)
1,000 m/s
200 m/s
Mechanical life
2
2
ON for 2 s, OFF for 30 s
ON for 1 s, OFF for 30 s
ON for 1.5 s, OFF for 1.5 s
ON for 1 s, OFF for 3 s
ON for 0.5 s, OFF for 1.5 s
Operating frequency
Operating frequency
All Relays
–55 C to 70 C (with no icing)
–55 C to 60 C (with no icing)
2-,3-pole: 500,000 operations min.
4-pole:
4-pole: 100,000 operations min.
(at 1,800 operations/hr under rated load)
200,000 operations min.
Electrical life
100,000 operations
300,000 operations
4,000,000 operations
25,000 operations
500,000 operations
5,000,000 operations
6,000,000 operations
Electrical life
Electrical life

Related parts for PY11-0