WT30-AT001 Omron, WT30-AT001 Datasheet
WT30-AT001
Specifications of WT30-AT001
Related parts for WT30-AT001
WT30-AT001 Summary of contents
Page 1
... I/O slaves WT30-SMD16 WT30-SMD16-1 Note: An Antenna and Mounting Brackets are not included with the Wireless SS Terminal. ■ Accessories Antennas Model Type WT30-AT001 Magnet-base Antenna (2 antennas per set) WT30-AT002 Flat Diversity Antenna (1 antenna) WT30-AT003 Pencil Antenna (2 antennas per set) Communications Cables Model ...
Page 2
... Terminal construction Power supply and I/O Screwless terminal block (Phoenix Contact FFKDS/V1-5.08 or equivalent) Serial Safety standards Weight Note: 1. Provide a power supply of at least 15 W, considering the inrush current generated at startup. 2. Use the WT30-FT003 Surface Mounting Bracket when installing the WT30 in environments subject to vibration. ■ Wireless Interface Specifications Item Wave type Communication method ...
Page 3
... Make the detailed settings TEST, and SET mode. for RUN/TEST/SET mode. RS-232C Terminal Power supply terminal Connect the PLC, personal computer, etc. Supply power to the WT30. Serial communications setting switch Set the baud rate. ■ I/O Slave Station Node setting switch (WNODE) Set the unit number of the I/O Slave Station ...
Page 4
... WS (Wireless Status) Note: When using the WD30 as the Serial Master Station, the ERR indicator will light if normal I/O communications are not possible due to an error in the host network. WT30 Color Status Meaning (primary error) Green Lit Power is being supplied. Not lit Power is not being supplied ...
Page 5
... Error output (NPN) Input voltage Allowable voltage Max. switching current Error output Leakage (PNP) current Residual 6 7 COM ERRP voltage Fuse 6 7 COM ERRN Error output (NPN) D-sub, 9-pin, Female End at WT30 Pin No. Signal 1 --- --- 2 RD Output 3 SD Input 4 --- --- 5 SG --- 6 --- --- 7 --- ...
Page 6
... Output Circuit Diagram (NPN COM (IN) Output Circuit Diagram (PNP) V ERRP ERRN G I/O Slave Station WT30-SID16 WT30-SMD16 WT30-SMD16-1 13.3 WT30 V OUT 0 OUT 1 Fuse OUT 2 Fuse OUT 7 Fuse G Fuse V OUT 0 OUT 1 Fuse OUT 2 OUT 3 OUT 7 G 105 90 DIN rail mounting bracket WT30-FT001 or WT30-FT002 7.3 ...
Page 7
... With Magnet-base Antenna WT30-AT001 (34) R38 R40 (32) 4.6 (38) I/O Slave Station DIN Rail mounting bracket WT30-FT001 or WT30-FT002 Magnet-base Antenna WT30-AT001 115 2010 35.8 dia. 39 DIN Rail Mounting Bracket WT30-FT001 WT30-FT002 With Flat Diversity Antenna WT30-AT002 (23) R50 20 I/O Slave Station DIN Rail mounting bracket ...
Page 8
... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...
Page 9
... Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at www.omron247.com – under the “About Us” tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. ...