MLX91206LDC-CALB

Manufacturer Part Number
MLX91206LDC-CALB
Description
IC SENSOR TRIAXIS SOIC-8
Manufacturer
Melexis Inc
Series
Triaxis™r
Datasheet

Specifications of MLX91206LDC-CALB

Current - Sensing
±10mT
Accuracy
±0.75%
Sensitivity
100 ~ 700 mV/mT
Current - Supply
9mA
Sensor Type
Hall Effect
Voltage - Supply
4.5 V ~ 5.5 V
Output
Analog, Ratiometric
Frequency
50kHz ~ 90kHz
Response Time
8µs
Polarization
Bidirectional
Operating Temperature
-40°C ~ 150°C
Package / Case
8-SOIC (0.154", 3.90mm Width)
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
MLX91206LDC-CAL
MLX91206LDC-LB
MLX91206LDC-LB
MLX91206LDC-LB-TU
The polarity of the Hall plate versus the output signal is programmable by the PLATEPOL parameter.
The sensitivity is programmable with 3 bits for ROUGHGAIN and 10 bits for FINEGAIN in analog output
application from 50 to 300 V/T (91206-High-Field version) and from 100 to 700 V/T (Low-Field version).
The FINEGAIN resolution depends on the programmed ROUGHGAIN setting. It typically ranges from
0.25V/T (ROUGHGAIN=7) up to 0.01V/T (ROUGHGAIN=0)
Note: Power consumption is 2mA less if ROUGHGAIN
XA
In analog mode
In PWM mode
YA
Not used in analog mode
In PWM mode
3901091206
Rev 034
11.6 Platepol (PLATEPOL)
11.7 Sensitivity programming (ROUGHGAIN, FINEGAIN)
11.8 Offset / output quiescent voltage programming (XA, YA)
PLATEPOL
12-bit register
Offset compensation before gain
@ 0 Gauss w/o offset & @Vdd=5V
Programming resolution:1.5mV per LSB over the full output range. This corresponds to a calibration
resolution of 0.03%Vdd
14-bit register – digital offset VOQ
Offset compensation before gain
9-bit register
Rough offset compensation (after gain)
Polarity
Vout = 6.25 * (VOQ Code) / 4096 (clipping can occur!)
Page 12 of 24
3
Triaxis Current Sensor IC
MLX91206
Data Sheet
May-11