SENSOR CURRENT 50A 5V MOD

HASS 50-S

Manufacturer Part Number
HASS 50-S
Description
SENSOR CURRENT 50A 5V MOD
Manufacturer
LEM USA Inc
Series
HASSr
Datasheet

Specifications of HASS 50-S

Current - Sensing
50A
Accuracy
±1%
Sensitivity
-
Current - Supply
22mA
Sensor Type
Open Loop Hall Effect
Voltage - Supply
5V
Output
-
Frequency
50kHz
Polarization
Bidirectional
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
398-1062
Current Transducer HASS 50..600-S
T
T
m
V
V
V
V
dCp
dCl
CTI
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
110512/12
A
S
b
d
e
w
General data
Isolation characteristics
Ambient operating temperature
Ambient storage temperature
Mass
Standards
Rated isolation voltage rms with following conditions
-Over voltage category Ⅲ
-Pollution degree 2
-Heterogeneous field
Rms voltage for AC isolation test, 50 Hz, 1 min
Partial discharge extinction voltage rms @ 10 pC
Impulse withstand voltage 1.2/50 µs
Creepage distance
Clearance distance
Comparative Tracking Index (Group I)
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
- 40 .. + 85
- 40 .. + 85
55
EN 50178:1997
3.3
> 1
6
> 5.5
> 5.5
> 600
mm
mm
kV
kV
kV
°C
°C
V
g
www.lem.com