HY 50-P LEM USA Inc, HY 50-P Datasheet - Page 2

no-image

HY 50-P

Manufacturer Part Number
HY 50-P
Description
SENSOR CURRENT 50A -+15V 6PIN
Manufacturer
LEM USA Inc
Series
HYr
Datasheet

Specifications of HY 50-P

Current - Sensing
50A
Accuracy
±1%
Sensitivity
-
Current - Supply
±10mA
Sensor Type
Open Loop Hall Effect
Voltage - Supply
±12 V ~ 15 V
Output
±4V
Frequency
50kHz
Polarization
Bidirectional
Operating Temperature
-10°C ~ 80°C
Package / Case
Module
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
398-1106
Dimensions HY 50-P
061027/5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
HY 50-P
97/02B
PCB MOUNTING DIMENSIONS
HY 50-P
(in mm. 1 mm = 0.0394 inch)
3.0
3 x 2.54
3 x 2.54
±0.5
4 holes dia 1
1 2 3 4
12.0
JAPAN
18.0
32.0 Max.
36.0 Max.
5.5
17.5
3.5
17.5
±0.2
±0.3
HY 50 - P
5
HY 50-P
(in mm ±0.1, hole -0, +0.2)
5.5
45059
9708
JP2
6
holes dia 2.2
3.5
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
PIN ARRANGEMENT
2 --15V
3 OUTPUT
4 0V
5 PRIMARY IN
6 PRIMARY OUT
1 +15V
1.6
PRELIMINARY
3.9
1.6
7.0
±0.3
±0.3
12 Max.
±0.2
www.lem.com
Page 2/2