DFT-110 SSI Technologies Inc, DFT-110 Datasheet - Page 2

SENSOR DRUM GAUGE 55GALLON LCD

DFT-110

Manufacturer Part Number
DFT-110
Description
SENSOR DRUM GAUGE 55GALLON LCD
Manufacturer
SSI Technologies Inc
Series
Digital Fluid-Trac™r
Type
Liquidr
Datasheet

Specifications of DFT-110

Output Configuration
LCD Display
Mounting Type
Male 2" (50.8mm) NPT
Material - Housing & Prism
-
Operating Temperature
0°C ~ 50°C
Voltage Rating
-
Minimum Liquid Specific Gravity
-
Switch Actuation Level
-
Current
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
734-1162
DFT-100
DFT-100-R
Measurement Technology
The Digital Fluid-Trac™ DFT-110 drum level gauge
uses ultrasonic technology to generate a high-
frequency sound wave and measures the time for the
echo to reflect off the target fluid’s surface and return.
The distance from the Digital Fluid-Trac’s sensor to the
liquid is calculated based on the speed of sound.
The Digital Fluid-Trac™ DFT-110 has a LCD which
displays the liquid level pictorially as well as in gallon
(or liter) units. The display shows the level reading
from the last time the Refresh/Select button was
pressed.
When the Refresh/Select button is pressed and
released, the DFT-110’s back-light is illuminated and
8.8.8. is displayed for 4 seconds to indicate the unit is
in test mode. The unit continuously monitors the
media in the vertical drum for 7 seconds and then
displays the liquid level. The level reading will remain
static until the Refresh/Select button is depressed
again.
20 seconds after the button was pressed, the unit will
go into a battery saver mode where the back-light is
shut off. The liquid level reading will be displayed for
5 minutes before the display turns off.
.
A low level warning light (red LED located on the
bottom left of the LCD display), will flash once every
second when the liquid level is <= 10% the maximum
volume. Note: This warning light does not operate
once the unit has powered down in battery saver
mode.
SSI TECHNOLOGIES, INC.
Controls Division
2643 W. Court Street
Janesville, WI 53548-5011
Phone: (608)758-1500
Fax: (608) 758-2491
www.ssitechnologies.com
Digital Fluid-Trac™ (DFT-110) Multi-Unit Drum Gauge
SSI Technologies – Application Note DT-AN5
Product Overview
Page 2
Electrical Interface
The Digital Fluid-Trac™ DFT-110 drum gauge is
powered by two 9 volt batteries (not included). The unit
can run on alkaline or lithium batteries.
If the battery life is low (voltage is below 14.2 volts),
“LoB “ will continuously flash to notify the user to
replace the batteries.
Displaying the DFT-110 Setting
a) Press and hold the Refresh/Select button
b) Release the Refresh/Select button and the
down for 7 seconds. The drum size will be
displayed. and the selected units (Liter or
Gallon) will be flashing.
unit will automatically go back into test
mode (indicated by 8.8.8) in 20 seconds.
Copyright April 21, 2009
SSI Technologies Inc.
All Rights Reserved
Revision 1
RoHS