FLUKE-190-202/AM Fluke Electronics, FLUKE-190-202/AM Datasheet - Page 5

no-image

FLUKE-190-202/AM

Manufacturer Part Number
FLUKE-190-202/AM
Description
SCOPEMETER 2CH 200MHZ COLOR AMER
Manufacturer
Fluke Electronics
Series
ScopeMeter® 190r
Type
Handheldr

Specifications of FLUKE-190-202/AM

Bandwidth
200MHz
Channels
2
Display Type
LCD - Color
Features
DMM, USB Interface, Save, Recall, Record, Trend
Probe Type
10:1 Voltage Probe (1 Blue, 1 Red)
Sampling Rate (per Second)
2.5GS/s
Input Impedance
1M
Rise Time (typ)
1.7nS
Voltage - Input (max)
CAT III 1000V, CAT IV 600V
Voltage - Supply
7.2V Battery, 17.8VDC Adapter
Includes
Alligator Clips, Battery Charger/Adapter, Hook Clips, Probe Set, Test Leads
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
614-1172
Recorder Modes
ScopeRecord
Dual or multiple input waveform storage mode, using deep memory
Source and display
Bandwidth
Memory depth
Min/max values
Recording modes
Stop-on-trigger
Horizontal scale
Zoom
Memory
ScopeRecord
Time base range
Recorded timespan
Time/division in ‘view all’ mode
Glitch capture
Sample rate
Resolution
Trendplot
Multiple channel electronic paperless recorder
Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time
Source and display
Memory depth
Ranges
Recorded time span
Recording mode
Measurement speed
Horizontal scale
Zoom
Memory
Cursor measurements – all recorder modes
Source
Dual vertical lines
Recording
Roll Mode
Roll mode sample rate and recording timespan
Any combination of scope measurements, made on any of the input channels, or DMM reading
(2-channel instruments)
18,000 points (sets) per measurement
Each recorded sample point contains a minimum, a maximum and an average value,
plus a date- and timestamp
Normal view: 5 s/div to 30 min/div
In view-all mode: 5 min/div to 48 hr/div (overview of total record)
Up to 22 days, with a resolution of 102 seconds
Continuous recording, starting at 5 s/div with automatic record compression
3 automatic measurements per second or more
Time from start, time of day
Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail
Two multiple input TrendPlot records can be saved internally for later recall and analysis
Direct storage on external flash memory drive through USB host port
Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot)
Cursors may be used to identify Min, Max or Average value of any datapoint in a record, with time
between cursors, time from start or absolute time
ScopeRecord mode can be stopped by an individual trigger event, or by an interruption of a repetitive
190-062
Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis
Ranges from full record overview to zoom in up to sample level, at any record length
All channels sampled simultaneously
trigger signal, through any input channel (through External on 190-XX2 Series)
Start-on-Trigger (through external),
Min/max values are created at samples that are measured at high sample rate
Stop-on-Trigger (through external)
Single sweep, continuous roll,
Direct storage on external flash memory drive through USB host port
Input A, Input B, Dual
30,000 data points, each holding min/max pair of information
190-102
ensuring capture and display of glitches
20 MHz or 20 kHz, user selectable
Time from start, time of day
5 ms/div ~ 2 min/div
200 μsec ~ 4.8 sec
0.5 s/div ~ 4 h/div
6 sec ~ 48 hr
190-202
125 MS/s
8 ns
ScopeMeter 190 Series II
Start-on-Trigger (through any channel),
Stop-on-Trigger (through any channel)
All channels sampled simultaneously
190-104
Single sweep, continuous roll,
Any combination of inputs,
up to 4 channels
Fluke Corporation 5
190-204