FLUKE-190-104/AM Fluke Electronics, FLUKE-190-104/AM Datasheet - Page 3

no-image

FLUKE-190-104/AM

Manufacturer Part Number
FLUKE-190-104/AM
Description
SCOPEMETER 4CH 100MHZ COLOR AMER
Manufacturer
Fluke Electronics
Series
ScopeMeter® 190r
Type
Handheldr

Specifications of FLUKE-190-104/AM

Bandwidth
100MHz
Channels
4
Display Type
LCD - Color
Features
DMM, USB Interface, Save, Recall, Record, Trend
Probe Type
10:1 Voltage Probe (1 Blue, 1 Green, 1 Red, 1 Gray)
Sampling Rate (per Second)
1.25GS/s
Input Impedance
1M
Rise Time (typ)
3.5nS
Voltage - Input (max)
CAT III 1000V, CAT IV 600V
Voltage - Supply
7.2V Battery, 17.8VDC Adapter
Includes
Alligator Clips, Battery Charger/Adapter, Case, Hook Clips, Probe Set, Software, Test Leads, USB Cable
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
614-1176
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is
seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on
glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events
Replay
Replay storage
FFT – frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window
Automatic window
Vertical scale
Frequency axis
Waveform compare and pass/fail testing
Waveform Compare
Pass/Fail Testing
Automatic scope measurements
Vdc, Vac rms, Vac+dc, Vpeak max, Vpeak min, Vpeak to peak, Aac, Adc, Aac+dc, frequency (in Hz), risetime (using cursors), falltime (using
cursors), phase (between any 2 inputs), pulsewidth (pos./neg.), dutycycle (pos./neg.), temperature °C, temperature °F (not for Japan), dBV, dBm
into 50 Ω and 600 Ω
Advanced power and motor drive
functions
Advanced functions
Cursor measurements
Source
Dual horizontal lines
Dual vertical lines
Single vertical line
ZOOM
Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual
control. Each screen has date and time-stamp
Two sets of 100 screens each can be saved internally for later recall and analysis
Direct storage of additional sets on external flash memory drive through USB host port
Automatic, Hamming, Hanning or None
Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant
Linear / Logarithmic (in volts or amps)
Frequency range automatically set as a function of timebase range of oscilloscope
Provides storage and display of a reference waveform for visual comparison with newly acquired
waveforms. Reference is derived from an acquired waveform and can be modified in the ScopeMeter
In waveform compare mode, the ScopeMeter can be set up to store only matching (“Pass”) or only
non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis
V/Hz ratio (190-x02 only), Power Factor (PF), Watts, VA, VA reactive, V
measurement on pulsewidth modulated motordrives and frequency inverters
mA*s (current-over-time, between cursors);
V*s (voltage over time, between cursors);
W*s (energy, between cursors)
On any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Voltage at cursor 1 and at cursor 2, voltage between cursors
Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers,
falltime with markers; Vrms between cursors, Watts between cursors
Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency
component in the FFT Resultant
Ranges from full record overview to zoom in up to sample level, at any record length
ScopeMeter 190 Series II
PWM
ac and V
PWM
(ac+dc) for
Fluke Corporation 3