JSH-42L3AD3-20 JDS UNIPHASE, JSH-42L3AD3-20 Datasheet - Page 24

no-image

JSH-42L3AD3-20

Manufacturer Part Number
JSH-42L3AD3-20
Description
Manufacturer
JDS UNIPHASE
Datasheet

Specifications of JSH-42L3AD3-20

Number Of Receivers
1
Operating Supply Voltage (typ)
3.3V
Operating Temperature Classification
Commercial
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Operating Temperature (max)
85C
Lead Free Status / Rohs Status
Compliant
JSH-42L3AD3-20S / 64P0682
LW 4x/2x/1x FC SFP with DDM
SFF 8472 Monitored Values
JDSU Product Specification 21121822-001
Page 24 of 45
Received Optical Power Meter Dynamic Range
Received Optical Power Meter Accuracy
Transmitted Optical Power Meter Dynamic Range
Transmitted Optical Power Meter Accuracy
Laser Bias Current Meter Dynamic Range
Laser Bias Current Meter Accuracy
Power Supply Voltage Meter Dynamic Range
Power Supply Voltage Meter Accuracy
Transceiver Temperature Meter Dynamic Range
Transceiver Temperature Meter Accuracy
1. Actual optical power incident on the receiver. This range, when coupled with the accuracy specified means that the power meter
2. When transceiver is operated within its specified temperature and power supply voltage dynamic operating ranges.
3. When optical input power is within the optical power meter specified dynamic operating range.
can read from -18 dBm to +3 dBm when input optical power is in the range -16 dBm to +1 dBm.
Parameter
-0.90
-0.10
-2.0
-2.0
Min
-20
4.0
2.8
-40
-9
-3
+0.90
Max
+1.0
+2.0
+2.0
0.10
-1.0
100
4.5
90
+3
Units
dBm
dBm
mA
mA
dB
dB
°C
°C
V
V
October 2008
Notes
2,3
1
2
2
2
2
2
2
2
2