Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
09-2010, Rev. 0910
www.tycoelectronics.com
© 2010 Tyco Electronics Ltd.
Approvals
cULus 508 File No. E 111441
Technical data of approved types on request
Contact Data
Contact arrangement
Max. switching voltage
Rated current
Limiting continuous current
Switching power
Contact material
Contact style
Min. recommended contact load
Initial contact resistance
Thermoelectric potential
Operate time
Release time,
Set/reset time min.
Bounce time max.
Electrical endurance
Contact ratings, UL contact rating
Mechanical endurance
Telecom/signal relay (dry circuit, test access, ringing)
Slim line 14x9mm (.551x.354”)
Switching current 2A
2 form C bifurcated contacts (2 CO)
High sensitivity results in low nominal power consumption, 80mW
for high sensitive, 140mW for sensitive version
High mechanical shock resistance, up to 300g functional, up to
1500g survival
without diode in parallel
with diode in parallel
contact application 0 (≤30mV/≤10mA) min. 2.5x10
cable load open end
resistive, 24V / 1.25A - 30W
resistive, 30VDC / 2A - 60W
resistive, 125VDC / 0.24A - 30W
Max. DC load breaking capacity
Signal Relays
FP2 Relay
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
250VAC, 0.25A, 62.5VA
min. 2.0x10
125VAC, 0.5A, 62.5VA
min. 5x10
min. 5x10
min. 5x10
220VDC, 0.24A, 60W
125VDC, 0.24A, 30W
typ. 3ms, max. 4ms
typ. 1ms, max. 3ms
typ. 3ms, max. 4ms
typ. 1ms, max. 5ms
100x10
DC current [A]
PdRu, Au covered
220VDC, 250VAC
30VDC, 2A, 60W
2 form C (CO)
twin contacts
60W, 62.5VA
100µV/1µA
<50mΩ
<10µV
20ms
6
2A
2A
5
5
5
operations
6
6
operations
operations
operations
operations
operations
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
Coil Data
Magnetic system
Coil voltage range
Max. coil temperature
Thermal resistance
Coil versions, monostable
Standard version, monostable
High sensitive version, monostable
All figures are given for coil without pre-energization, at ambient temperature +23°C.
24
25
26
27
28
Coil
code
06
04
09
05
10
02
12
13
21
22
23
Coil Operating Range
3.4
3.2
2.8
2.6
2.4
2.2
1.8
1.6
1.4
1.2
0.8
0.6
0.4
0.2
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
3
2
1
0
-60
voltage
Rated
VDC
U
4.5
4.5
-50
12
24
48
12
24
48
nom.
3
5
6
9
3
5
6
9
-40
nominal coil voltage
-30
Operate
-20
voltage
16.80
33.60
16.80
36.00
VDC
2.10
3.15
3.50
4.20
6.30
8.40
2.10
3.15
3.50
4.20
6.30
8.40
-10
Ambient Temperature [°C]
0
10
Limiting
voltage
11.00
13.20
19.80
26.40
44.30
72.30
13.10
14.60
17.50
24.20
35.00
52.80
77.60
20
VDC
6.60
9.90
8.70
30
bistable 1 coil, bistable 2 coils
Telecom-, Signal and RF Relays
FP2 Relay
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
40
50
polarized, monostable,
Release
U
U
voltage
VDC
0.30
0.45
0.50
0.60
0.90
1.20
2.40
4.80
op. min.
rel. min.
0.30
0.45
0.50
0.60
0.90
1.20
2.40
4.80
60
3 to 48VDC
70
<150K/W
125°C.
U
U
U
80
U
U
U
max.
max.
max.
max.
max.
max.
resistance
90
Z
Ω±10%
at 0 A
at 2 x 1 A
at 2 x 2 A
140 mW
200 mW
at 0 A
at 2 x 1 A
at 2 x 2 A
1028
2880
7680
1013
1800
4114
8882
260 mW
300 mW
145
178
257
574
113
353
313
450
Coil
80 mW
100 110 120
64
Axicom
Rated coil
power
mW
140
140
140
140
140
140
200
300
140
260
80
80
80
80
80
80
U
U
U
U
nom
max
op. min.
rel. min.
1
=
=
=
=