Typical applications
Communications equipment, linecard application - analog, ISDN, xDSL,
PABX, voice over IP, office and business equipment, measurement and
control equipment, consumer electronics, set top boxes, HiFi, medical
equipment
09-2010, Rev. 0910
www.tycoelectronics.com
© 2010 Tyco Electronics Ltd.
Approvals
cULus 508 File No. E 111441
Technical data of approved types on request
Contact Data
Contact arrangement
Max. switching voltage
Rated current
Limiting continuous current
Switching power
Contact material
Contact style
Min. recommended contact load
Initial contact resistance
Thermoelectric potential
Operate time
Release time
Set/reset time min.
Bounce time max.
Electrical endurance
Contact ratings UL contact rating
Mechanical endurance
Slim line 15x7.3mm (.590x.287”)
2 form C bifurcated contacts (2 CO), switching current 2A
High sensitivity for low power consumption, 80mW/140mW
High dielectric characteristic, ≤1800Vrms between open contact
High surge capability (1.2/50μs and 10/700μs) meets Telcordia GR
1089 and FCC Part 68, ≤2500V between open contacts, ≤3500V
between coil and contacts
High mechanical shock, up to 300g functional, up to 1500g survival
Hermetically sealed (RT V)
without diode in parallel
with diode in parallel
at contact application 0
(≤ 30mV / ≤ 10mA)
cable load open end
resistive, 24V / 1.25A - 30W
resistive, 30VDC / 2A - 60W
resistive, 125VDC / 0.24A - 30W
Max. DC load breaking capacity
Signal Relays
FX2 Relay
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
250VAC, 0.25A, 62.5VA
min. 2.5x10
min. 2.0x10
125VAC, 0.5A, 62.5VA
min. 5x10
min. 5x10
min. 5x10
220VDC, 0.24A, 60W
125VDC, 0.24A, 30W
typ. 3ms, max. 4ms
typ. 1ms, max. 3ms
typ. 3ms, max. 4ms
typ. 1ms, max. 5ms
100x10
DC current [A]
PdRu, Au covered
220VDC, 250VAC
30VDC, 2A, 60W
2 form C (CO)
twin contacts
60W, 62.5VA
100µV/1µA
<70mΩ
<10µV
20ms
6
2A
2A
5
5
5
operations
6
6
operations
operations
operations
operations
operations
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.tycoelectronics.com/definitions
Coil Data
Magnetic system
Coil voltage range
Max. coil temperature
Thermal resistance
Coil versions, monostable
Standard version, monostable, 1 coil
High sensitive version, monostable, 1 coil
High dielectric version, monostable, 1 coil
All figures are given for coil without pre-energization, at ambient temperature +23°C.
23
24
25
26
27
28
91
92
96
Coil
code
06
07
04
09
05
10
02
12
13
21
22
Coil Operating Range
3.4
3.2
2.8
2.6
2.4
2.2
1.8
1.6
1.4
1.2
0.8
0.6
0.4
0.2
2.6
2.4
2.2
2.0
3
2
1
0
-60
voltage
Rated
VDC
-50
U
4.5
4.5
4.5
12
24
48
12
24
48
12
nom.
3
4
5
6
9
3
5
6
9
3
-40
nominal coil voltage
-30
-20
Operate
voltage
16.80
33.60
16.80
36.00
VDC
2.10
2.80
3.15
3.50
4.20
6.30
8.40
2.10
3.15
3.50
4.20
6.30
8.40
2.25
3.15
8.40
-10
Ambient Temperature [°C]
0
10
Limiting
20
voltage
10.50
12.60
18.90
25.20
42.20
68.90
11.10
12.50
13.90
16.70
33.40
50.40
70.00
25.2
VDC
6.30
8.40
9.40
8.30
6.3
9.45
30
AXICOM
Telecom-, Signal and RF Relays
FX2 Relay
40
polarized, monostable, bistable
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
50
U
U
Release
op. min.
rel. min.
voltage
60
VDC
4.80
0.30
0.45
0.50
0.60
0.90
1.20
2.40
4.80
0.30
0.45
1.20
0.30
0.40
0.45
0.50
0.60
0.90
1.20
2.40
70
3 to 48VDC
Z
U
U
U
<165K/W
80
U
U
U
max.
max.
max.
125°C.
max.
max.
max.
90
at 0 A
at 2 x 1 A
at 2 x 2 A
resistance
140 mW
200 mW
at 0 A
at 2 x 1 A
at 2 x 2 A
Ω±10%
80 mW
260 mW
300 mW
100 110 120
1028
2880
7680
1013
1800
4114
8882
114
145
178
257
574
113
353
313
450
101
720
Coil
64
45
Axicom
Rated coil
power
mW
140
140
140
140
140
140
140
200
300
140
260
200
200
200
80
80
80
80
80
80
Unom =
Umax. =
Uop. min. =
Urel. min. =
1