HIH-6131-021-001 Honeywell Sensing and Control, HIH-6131-021-001 Datasheet - Page 7

no-image

HIH-6131-021-001

Manufacturer Part Number
HIH-6131-021-001
Description
SENSOR HUMIDITY 3.3V 5% SMD
Manufacturer
Honeywell Sensing and Control

Specifications of HIH-6131-021-001

Mfg Application Notes
HIH-6130,6131 Medical, Industrial Appl
Output Type
I²C™
Sensor Type
Humidity and Temperature
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
480-3652-2
Figure 6. Nomenclature
Order Guide
SENSOR REHYDRATION
To rehydrate the sensor, expose it to room temperature under
ambient conditions (>50 %RH) for a minimum of five hours.
Catalog Listing
HIH-6130-021-001
HIH-6130-021-001S
HIH-6131-021-001
HIH-6131-021-001S
NOTICE
SENSOR REHYDRATION
Exposure to elevated temperatures, such as those
experienced during solder reflow, may dry out the sensing
element. It is recommended that the sensor be allowed
time to rehydrate after soldering or other high
temperature/dry exposures.
Exposure to these conditions will not permanently
damage the sensor. It will generally return to its factory-
calibrated value after rehydration.
If rehydration is not performed, the sensor may read a
slight offset that slowly disappears over time as the
sensor becomes exposed to ambient conditions.
Conversely, extended exposure to condensing and high
humidity environments (>90 %RH) may cause a revisable
shift in readings which will generally return to normal after
the sensor has been allowed to dry off.
Supply Voltage
1 = 2.3 Vdc to 5.5 Vdc, calibrated at 3.3 Vdc
Description
Honeywell HumidIcon™ Digital Humidity/Temperature Sensors: HIH-6130/6131 Series, I
total error band, SOIC-8 SMD, no filter, non-condensing, 1000 units on tape and reel
Honeywell HumidIcon™ Digital Humidity/Temperature Sensors: HIH-6130/6131 Series, I
total error band, SOIC-8 SMD, no filter, non-condensing, five units on tape (sample)
Honeywell HumidIcon™ Digital Humidity/Temperature Sensors: HIH-6130/6131 Series, I
total error band, SOIC-8 SMD, hydrophobic filter, condensation-resistant, 1000 units on tape and reel
Honeywell HumidIcon™ Digital Humidity/Temperature Sensors: HIH-6130/6131 Series, I
total error band, SOIC-8 SMD, hydrophobic filter, condensation-resistant, five units on tape (sample)
Product Type
HIH = Humidity sensor
Filter
0 = No filter
1 = Hydrophobic filter
Output Type
6 = Digital
Package
3 = SOIC-8 SMD
HIH – 6 1 3 _ - _ _ _ - _ _ _ _
ADDITIONAL INFORMATION
The following associated literature is available on the Web:
– Humidity Sensor Performance Characteristics
– Humidity Sensor Theory and Behavior
– Humidity Sensor Moisture and Psychrometrics
– Humidity Sensor Chemical Resistivity
– Thermoset Polymer-based Capacitive Sensors
– I
– Using Alarms on the Honeywell HumidIcon™ Digital
– Entering and Using Command Mode on the Honeywell
– Total Error Band Specification for Honeywell Digital
Product installation instructions
Product application note
Application sheets:
Technical Notes:
Digital Humidity/Temperature Sensors: HIH-6130/6131
Series
Humidity/Temperature Sensors: HIH-6130/6131 Series
HumidIcon™ Digital Humidity/Temperature Sensors:
HIH-6130/6131 Series
Humidity/Temperature Sensors
2
C Communication with the Honeywell HumidIcon™
HIH-6130/6131 Series
Packaging
001 = 1000 pieces, tape and reel
001S = 5 pieces, tape and reel (sample)
Output
21 = I
Accuracy
0 = ±4 %RH
2
C, address 0x27, alarms
Honeywell Sensing and Control
2
2
2
2
C, ±5 %RH
C, ±5 %RH
C, ±5 %RH
C, ±5 %RH
7

Related parts for HIH-6131-021-001