125XBRIRBA24D EDWARDS SIGNALING PRODUCTS, 125XBRIRBA24D Datasheet - Page 2

40T9952

125XBRIRBA24D

Manufacturer Part Number
125XBRIRBA24D
Description
40T9952
Manufacturer
EDWARDS SIGNALING PRODUCTS
Datasheet

Specifications of 125XBRIRBA24D

Current Rating
150mA
Flash Rate Per Minute
240
Length
98.4mm
Ip/nema Rating
NEMA 4X
Supply Voltage
24VDC
Light Source
LED
*Clear
** LED Manufacturer’s Median Projected LED Life for LUXEON Rebel LEDs (L70 at 85ºC and T
Gasket (provided for use
when direct panel mounting)
1638 Listed
Description
LED Multi-Status Indicator
in NEMA 4X Enclosure
Cat. No.
125XBRiRGA24D
125XBRiRGA120A
125XBRiRBA24D
125XBRiRBA120A
125XBRiRGA24DB
125XBRiRGA120AB
125XBRiRBA24DB
125XBRiRBA120B
Dimensional Drawing
Double threaded for
panel mounting or
1/2" internal or
3/4" external
conduit mounting
Agency Approvals
125XBRi Series
Chameleon
temperature and duty-cycle at which the signaling device is operated. Please refer to http://www.philipslumileds.com/pdfs/WP15.pdf.
PLC Output to Meet Input
Parameter Specifications
Enclosure
NEMA 4X
Listed
Listed
Cat. No.
125XBRiRGA24D
125XBRiRGA120A
125XBRiRBA24D
125XBRiRBA120A
125XBRiRGA24DB
125XBRiRGA120AB
125XBRiRBA24DB
125XBRiRBA120B
120 VAC 50/60 Hz
120 VAC 50/60 Hz
120 VAC 50/60 Hz
120 VAC 50/60 Hz
Operating
Voltage
24 VDC
24 VDC
24 VDC
24 VDC
3.25"
(82.6mm)
(98.4mm)
Base Color
3.875"
Locknut - 1.3625" O.D. (provided
for use when direct panel
mounting)
Black
Black
Black
Black
Gray
Gray
Gray
Gray
Red, Green, Amber
Red, Green, Amber
Red, Blue, Amber
Red, Blue, Amber
Red, Green, Amber
Red, Green, Amber
Red, Blue, Amber
Red, Blue, Amber
Max. Off State Leakage
junction
41 Woodford Avenue
Plainville, CT 06062
1.800.336.4206
www.edwardssignaling.com
© Copyright 2010 Edwards Signaling
LED Colors
Current (mA)
98ºC). Actual LED life will vary inversely with ambient temperature, voltage, driver current, junction
5
5
5
5
5
5
5
5
Projected LED
148,000 hours
148,000 hours
148,000 hours
148,000 hours
148,000 hours
148,000 hours
148,000 hours
148,000 hours
Life (L70)**
Continuous On
Operating Voltage
Current (mA)
120 VAC 50/60 Hz
120 VAC 50/60 Hz
120 VAC 50/60 Hz
120 VAC 50/60 Hz
150
100
150
100
150
100
150
100
24 VDC
24 VDC
24 VDC
24 VDC
Not to be used for installation purposes.
Data Sheet ES001-0114 Issue 1
Current
0.150 A
0.100 A
0.150 A
0.100 A
0.150 A
0.100 A
0.150 A
0.100 A
28.5 A / 212 µSeconds
28.5 A / 212 µSeconds
28.5 A / 212 µSeconds
28.5 A / 212 µSeconds
28.5 A / 65 µSeconds
28.5 A / 65 µSeconds
28.5 A / 65 µSeconds
28.5 A / 65 µSeconds
(inrush / duration)
Replacement Lens
Surge
125LC*
125LC*
125LC*
125LC*
125LC*
125LC*
125LC*
125LC*
Page 2 of 2